EN
21
Installation
www.bora.com
5.9 Basic configuration
When installation is complete, you must carry out the basic
settings (these settings can be changed at any time later on).
i
You can see precise instructions on the basic
configuration and all necessary information in the
Configuration menu chapter of the operating instructions.
X
X
Follow the instructions on the basic configuration (see
Operating instructions – “Configuration menu” chapter).
5.10 Initial operation
i
You will find detailed information on operating the BORA
Professional 3.0 system in the operating instructions (see
“Functions and operation” chapter).
X
X
Ensure that all appliances are connected correctly and
connected to the power supply (fused) prior to initial
operation.
X
O
Exception: During initial operation, the kitchen fitter may use
a temporary power supply for the control unit in order to carry
out the basic configuration (e.g. using the site power supply
during the building phase).
X
O
The settings made are saved and will not be affected when the
system is disconnected from the mains.
X
O
The final mains connection to the appliances may only be set
up by certified specialists.
5.11 Function test
X
X
Carry out a thorough function test on all appliances.
X
X
In the event of error messages, see the “Troubleshooting”
chapter in the operating instructions.
Special information for the Tepan stainless steel grill
PKT3:
i
This appliance is intended to be operated on a supply
network with an impedance Zmax at the transfer point
(mains connection) of 0.116 ohms maximum. The user
is to ensure that the appliance is only operated on a
mains supply network which meets this requirement. If
necessary, ask the local energy supply company about
the system impedance.
Connecting the cooktop to the power supply
The power supply cable to be used (already pre-installed) must
comply with certain, appliance-specific requirements (see table
“Fuse protection and minimum cross-section”).
i
A damaged power supply cable must be replaced by
another suitable power supply cable. This may only be done
by an authorised member of the After Sales Service team.
Power supply cable requirements and connection diagram
Connection Fuse
protection
Minimum
cross-section
Power supply
cable
1-phase
connection
1 x 25 A
2.5 mm²
Type H05V2V2-F
2-phase
connection
2 x 16 A
2.5 mm²
Type H05V2V2-F
Tab. 5.4
Fuse protection and minimum cross-section
1
L1
2
3
N
PE
220 - 240 V~
Fig. 5.24
1-phase connection diagram
1
L1
L2
2
N
PE
220 - 240 V~
220 - 240 V~
3
Fig. 5.25
2-phase connection diagram
Connecting the cooktop to the mains
X
X
Switch off the main switch/automatic circuit breaker before
connecting the cooktop.
X
X
Secure the main switch/automatic circuit breaker against
being switched back on without permission.
X
X
Make sure the power to the appliance is disconnected.
X
X
Only connect the cooktop using a permanent connection to a
power supply cable.
X
X
Check that installation has been carried out correctly.
X
X
Switch on the main switch/automatic circuit breaker.
X
X
Put the cooktop into operation (see the Operation chapter).
X
X
Check that all the functions are working correctly.