![bora PKCH3 Operating And Installation Instructions Download Page 16](http://html1.mh-extra.com/html/bora/pkch3/pkch3_operating-and-installation-instructions_2788192016.webp)
EN
16
Installation
www.bora.com
Cooktops/cooktop extractor
A in mm
B in mm
1/0
374
346
1/1
485
457
2/1
856
828
3/2
1338
1310
4/2
1709
1681
Tab. 5.2
Cut-out dimensions of the appliance combinations in
the case of flush installation
5.5.2 Surface mounting
x
B ±2
≤ R5
≥ 74
(≥ 70)
516 ±2
≥ 700
Fig. 5.7
Cut-out dimensions for surface mounting
12
10 - 40
Fig. 5.8
Overlay dimensions for surface mounting
5.5 Cut-out dimensions
i
All dimensions are shown from the front edge of the front
cover.
Worktop overhang
≥60
(≥74)
14
x
Fig. 5.4
Worktop overhang
X
X
Please note the worktop overhang x when creating the
worktop cut-out. Applies to flush installation and surface
mounting.
i
In the case of cooktop extractor PKA3/PKA3AB
combined with straight duct piece PKA1FEV, flush
installation is also possible in a worktop with a depth
≥ 650 mm.
5.5.1 Flush installation
x
A ±2
B ±2
544 ±2
≤ R5
≤ R5
≥ 74
(≥ 70)
516 ±2
≥ 700
Fig. 5.5
Cut-out dimensions for flush installation
7 +0,5
14
10 - 40
Fig. 5.6
Rebate dimensions for flush installation
Summary of Contents for PKCH3
Page 33: ...EN 33 Notes www bora com 11 Notes...
Page 34: ...EN 34 Notes www bora com...