Operating Manual
Universal Flow Computer UR06
Bopp & Reuther
A-EN-08728-URRev.B
Subject to changes
Page 7 of 55
Messtechnik GmbH
1 Identification
Manufacturer:
Bopp & Reuther Messtechnik GmbH
Am Neuen Rheinhafen 4
67346 Speyer, Germany
Phone : +49 6232 657-0
Fax : +49 6232 657-505
Type of product:
Universal flow computer
Product name:
UR06
Version no.:
A-EN-08728-UR Rev.D (UR06; hardware: HV4; software: V0.57 or higher)
2 Area of Application
2.1 Intended use
UR06 is designed to measure energy and flow rates for gaseous, vaporous and liquid media. Various
types of volume, mass, flow, pressure, temperature and density transmitters can be connected. The
measured values and the set parameters are used according to generally acknowledged rules of
technology to form the media data. In order to further process the measured and calculated values, it
is possible to transfer the data via variably configurable standard interfaces.
2.2 Warning signs
At the time of delivery, the universal flow computer UR06 meets the highest technical specifications
and is generally safe to operate. It has been tested and left the factory in perfect working order.
However, careless or incorrect usage of the universal flow computer can result in hazardous
situations.
Therefore, always observe the warning signs.
2.3 Operational safety
UR06 must not be used in explosive areas.
The universal flow computer UR06 meets the following safety criteria:
Safety requirements in accordance with EN 61010-1:2001
Interference stability in accordance with EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,
EN 61000-4-5, EN 61000-4-6, EN 61000-4-8
Interference emit in accordance with EN 61326 Class A
Heat meters in accordance with EN 1434-4 Class C
Degree of protection provided by the housing IP 65 in accordance with EN 60529
Parameter and counter data is saved in the EEPROM during a power failure.
2.4 Personnel for installation, start-up and operation
Only trained personnel who have received authorization from the system owner are
allowed to carry out assembly, electrical installation, start-up, maintenance, and
operation. They should have read and understood the operating instructions and
always follow the information contained therein. Incorrect installation and start-up
can result in significant measuring errors or damage to the device.
Always adhere to national regulations.
Danger of death if the power supply is connected incorrectly.
2.5 Factory setting
The universal flow computer UR06 is supplied with a default configuration or set to the operating
conditions specified in the order.