Universal Flow Computer UR06
Operating Manual
Page 16 of 55
Subject to changes
A-EN-08728-URRev.B
Bopp & Reuther
Messtechnik GmbH
9.2 Plug-in unit
The UR06 plug-in unit has 3 - 4 removable 12-pole terminal blocks at the rear for the signal inputs and
outputs. Energy is supplied via an IEC connector (230 V). There is an additional socket (3.5 mm jack)
at the front for communication.
Terminal assignment:
J4
J3
J2
J1
1
1 OC 1+
4
1 MUS1
12
1 DI 1 +
26
2
2 OC 1-
5
2 I1
13
2 DI 1 -
27
3
3 OC 2+
6
3 GND
14
3 DI 2 +
28
4
4 OC 2-
7
4 MUS2
30
4 DI 2 -
29
5
5 OC 3+
8
5 I2
31
5 PT1 ++
15
6
6 OC 3-
9
6 GND
32
6 PT1 +
16
7
7
7 Iout1 +
22
7 PT1 -
17
8
8 M-Bus
1
8 Iout1 -
23
8 PT1 --
18
9
9 M-Bus
2
9 Iout2 +
24
9 PT2 ++
33
10
10 RS RxD
19
10 Iout2 -
25
10 PT2 +
34
11
11 RS TxD
20
11 24 V+
10
11 PT2 -
35
12
12 RS GND
21
12 24 V-
11
12 PT2 --
36
The numbers in the 3rd terminal block column relate to the terminal assignment of the standard
version. Terminal designations that start with the letter M relate to the module terminals.
J4 J3 J2 J1