background image


 

 

Contents 

 

Section 

Page  Section 

Page 

Introduction & Specification 

Fault Finding 

Installation & Commissioning  3 

Wiring Schematic 

Spare Parts 

Removal, Transportation  
and Disposal 

10 

 

 

Introduction 

The EXL651 is an ice-bank cooler designed for installation in a cupboard under a worktop, 
and  incorporates  two  water  cooling  coils.  It  can  either  be  installed  in  conjunction  with  a 
separate ambient carbonator, the EXL171, to provide still and carbonated water, or on its own 
to provide still water only. The pack includes air duct components that must be installed if the 
chiller is installed in an otherwise unventilated space. 

 

Specification 

 

Dimensions 

330mm(W) 
482mm(D) 
522mm(H) 

Compressor 

Cubigel 
GL60TB 

Dry Weight 

32.5kg 

This product contains fluorinated 
greenhouse gas with a GWP of 1300 
in an hermetically sealed system

 

Wet Weight 

45.0kg 

Supply 

230Vac/50Hz 

Refrigerant 

R134a, 120g 

Rated Input 

300W 

Climatic Class 

Rated Current 

2A 

 

 

Fuse Rating 

5A 

Net cooling power 
24°C ambient, during 
recovery. 

570W 

IP Rating 

N/A 

Nominal ice bank 

5kg 

 

 

 

 

Contents 

Introduction and Specification 

 

Summary of Contents for EXL651

Page 1: ...Product Manual EXL651 Still and Carbonated Water Cooler Part Number 3B6220 Issue A 24 05 16 ...

Page 2: ...and carbonated water or on its own to provide still water only The pack includes air duct components that must be installed if the chiller is installed in an otherwise unventilated space Specification Dimensions 330mm W 482mm D 522mm H Compressor Cubigel GL60TB Dry Weight 32 5kg This product contains fluorinated greenhouse gas with a GWP of 1300 in an hermetically sealed system Wet Weight 45 0kg S...

Page 3: ...iewed from the front Align template 3B4614 with the rear left hand side corner of the cabinet and mark through the corners of the two cut outs Cut out the openings taking care not to cut into any pipes or cables that may be located under the cabinet Align template 3B4615 with the top left corner of the kick board for the cabinet being used Again mark through and cut out the area for the exhaust du...

Page 4: ...der the bath overflow a small plastic bottle is provided for this purpose Fill the bath with cold water through the opening on the top of the machine until water is displaced from the over flow Connect power to the machine and switch on The fan and compressor will start and the machine will start to cool down The machine can now be connected to the other components of the water system and once a f...

Page 5: ...5 Installation and Commissioning ...

Page 6: ...134 140 36 32 238 82 82 54 206 62 Top View Front View Standard Cutout 72 60 425 50 Front View Extended Cutout All dimensions are based around a standard 600mm wide kitchen cabinet Installation and Commissioning ...

Page 7: ...7 Item No Description Part No 1 High Side Protector 3B3963 2 Axial Fan 1B5514 3 Agitator Assembly 1A5237 4 Control Thermostat 1A4714 Spare Parts ...

Page 8: ...e agitator is running If supply voltage is present renew agitator assembly If agitator is running with no water agitation check agitation blades Warm Drinks Insufficient air flow through the fridge Check that the condenser is not blocked Check for blockages and obstructions to ventilation grills If in enclosed cabinet check supplied ventilation kit is fitted and can ventilate to cool air supply Co...

Page 9: ...NS PLUG BU BR G Y BR L NC E N WH WH YE BU BU BU AGITATOR IEC CONNECTOR CARBONATOR IEC CONNECTOR CONDENSOR FANS COMPRESSOR CONTROL THERMOSTAT HIGH SIDE PROTECTOR NOTE SOME EARTH CABLES G Y OMITTED FOR CLARITY Wiring Schematic ...

Page 10: ...As with all refrigeration systems irreparable damage can be caused by laying the unit on its side or even transporting upside down Where the unit is transported by a carrier the carton should always be marked in a conspicuous manner the correct upright position in which it must be handled If a unit has been transported incorrectly it should be placed in the correct upright position and left for 24...