Your pump is the demand type. Meaning if you have no demand or
water flow it will not run/ make noise. If your solution control valve
is closed or the front sprayer valve is shut and the shower feed valve
is shut your pump will not flow and will not make any noise until
the solution valve is opened and either or both of the ball valves are
opened.
To prime the pump turn on the pump by switching on either the
momentary or continuous feature by pulling up or pushing down
the pump switch lever shown in (pic#2) and open the solution valve
(pic#1) all the way. If you still cannot prime the pump please call
877-477-1615.
(Pic#3) shows the configuration to operate the front sprayer. (Pic#4)
would should the front sprayer off and the satellite sprayer feed on.
When starting, using the front sprayer your initial setting might be
between the blue and silver colored rings on the solution control valve
(pic#1) For a setting using the shower feed you might start between
the orange and blue rings. For shower feed as you will usually use less
solution than the front sprayer. For the front sprayer try between the
blue and silver rings. These are just suggestions as you will quickly
determine the settings needs as you become familiar with your
machine.
note:
When using the shower feed and scrubbing pads allow
the solution to run over the pad holder for 5 or 6 seconds before you
start your machine so you have lubrication from the cleaning solution
on the carpet. Shower feed should not be used with bonnets, only
Revive Carpet Encapsulation Pads or Multi-Brush loaded with Revive
Pads.
operating the MiniMax Pump
7
Pic. 1
Pic. 2
Pic. 3
Pic. 4