n° 6BE648285NI-0606 –
Page 14
3.4.2 FLOOR FIXING CHANNEL
IMPORTANT : The floor fixing channels should be fixed to a perfectly flat and horizontal
floor.
With the stainless base option the channels are replaced by a radiused stainless sheet.
In this case, to avoid water infiltration the base should be sealed to the floor with mastic
particularly in the doorways.
1) Start by marking out the location on the floor following the diagram below :
2) Fix the channels to one another with the angle connections code 683530X then bolt
to the floor (floor fixings provided by the installer, M5 shot fired are recommended)
Model shown: 2x1C GI cabinet with 2 doors to the front
Model shown: 2x1C GI cabinet with 2 doors to the front
Door frame bracket
683530Y
Angle connection
683530X
Rear channels
683530A (U Lg.825)
683530B (D Lg.913)
683530B (G Lg.913)
683530B (M Lg.1000)
Side channels
683530A (1C Lg.825)
683530E (2C Lg.1650)
683530F (3C Lg.2475)