Instructions n°648261 –
Page 12
4. INTERVENTIONS AND REPAIRS
IMPORTANT
Before any operation, ensure that the appliance is unplugged.
4.1 ACCESS TO COMPRESSOR UNIT
To clean the condenser
f
, to access the unit and the electric box
e
remove the
control panel grid
h
.
4.1.1 MI 3 MODEL
1) Unscrew the 2 screws
g
2) Remove the grid
h
following
c
and
d
3) Remove the condenser fan
i
by
cutting the 2 "rilsan" rings
4) Clean the condenser
f
with a non
metallic brush with soft hair
5) Refix the fan with , 2 "rilsan" rings on
the condenser cross.
4.1.2 MI 6 and MI 10 MODELS
1) Unscrew the 2 screws
g
2) Remove the grid
h
following
c
and
d
3) Unscrew the 2 "star" screws
j
and
pivot the fan support following
i
4) Clean the condenser
f
with a non
metallic brush with soft hair.
5) Refix the fan by screwing the 2 "star"
screws
j
.
REMARKS
Unscrew the 4 nylon nuts to access the display card.
Take out the power box using rail, to access the micro card and to the connection
terminals.