12.4.5
0x3005/0 Boolean DeMux
Index Sub-index
Meaning
Data type Access Map Def.-Val
0x3005
0
Boolean DeMux
Unsigned16
rw
Rx
0
Via object 0x3005 up to 16 Boolean values can be written in a compressed manner.
These values are available as sources which can be chosen by the selection of
832 … 847
Obj 0x3005 Demux Out 1…16 from a parameters choice list.
Obj. 0x3005
Bit no. Source No.
Source name
0
832
Obj. 0x3005 Demux Out 1
1
833
Obj. 0x3005 Demux Out 2
2
834
Obj. 0x3005 Demux Out 3
3
835
Obj. 0x3005 Demux Out 4
4
836
Obj. 0x3005 Demux Out 5
5
837
Obj. 0x3005 Demux Out 6
6
838
Obj. 0x3005 Demux Out 7
7
839
Obj. 0x3005 Demux Out 8
8
840
Obj. 0x3005 Demux Out 9
9
841
Obj. 0x3005 Demux Out 10
10
842
Obj. 0x3005 Demux Out 11
11
843
Obj. 0x3005 Demux Out 12
12
844
Obj. 0x3005 Demux Out 13
13
845
Obj. 0x3005 Demux Out 14
14
846
Obj. 0x3005 Demux Out 15
15
847
Obj. 0x3005 Demux Out 16
07/13