1-866-771-2663 | Page 9
To Light
To Extinguish
Before performing a leak test, be sure that no sparks can occur and you are in a spacious outdoor
area. Connect the propane gas tank to the regulator and turn the valve on the unit to the “off”
position. Brush a soap and water mixture on all connections. Turn the gas supply on; if bubbles
occur on any connection there may be a leak.
If you smell gas or a leak is discovered turn the
gas valve off, disconnect propane gas tank and do not use the appliance until the leak is
repaired.
heating item.
1. Make sure the control knob (I) is in the “off” position.
2. Open drawer (C) and slowly open the valve on the propane gas tank by turning the knob
counterclockwise.
3. Replace the drawer (C) on the body (B).
4. Push and hold in the electronic ignit r (J) to create sparks within the electrode, continue to hold.
5. Push in the control knob (I) and turn to the “low” position. Keep holding down the control knob (I)
5 seconds.
6. If ignition doesn’t occur within a few seconds, release the control knob (I) and rotate to the “OFF”
position. Wait for 5 minutes for gas to clear and then repeat the above lighting instructions.
7.
between the “low” and “high” positions.
1. Turn control knob (I) clockwise to the “low” position; let the knob pop up and continue turning the
control knob (I) to the “off” position.
2. Close the cylinder valve on the propane gas tank if you don’t intend to use it for a long time.
OPERATION
Do not use the heating unit without inspecting the gas hose. If there are signs of wear or abrasion
you must replace the hose (if applicable).
Pumice stones/lava rocks/LavaGlass
®
could pop up and
strike somebody’
20 minutes after igniting. Flame height should be a yellow/blue color between
5.1 - 25.4 cm /
2 - 10 inches in height.