BOND MANUFACTURING 66637 Owner'S Manual Download Page 9

clockwise to off “    ”. Wait 5 minutes, 

Turn ignition control knob to the off “      ” position. Connect propane gas tank to regulator and 
Push the ignition control knob in and turn counterclockwise to the “       ” position; this will 

To adjust the flame, turn the ignition control knob either clockwise or counterclockwise

If ignition does NOT immediately take place in seconds, push and turn the ignition control knob 

 

 

 

 

 

 

 

 

 

 

LEAK TEST

 

 

1  Perform a leak test in a well ventilated area outside. 
2 Make 

sure 

any 

open 

flames 

or 

cigarettes 

are 

extinguished. 

3 Remove 

the 

battery. 

4  Ensure the burner control knob is in the "OFF" position. 
5  In a bowl, create a soap solution using 1 part water and 1 part liquid detergent. 
6  Apply the soapy water solution to all connections. 
7  Open LP tank valve. 
8  A gas leak will be detected by expanding bubbles originating  from the point of the leak. 
9  If a leak is found at any connection point or if you smell gas, close the tank valve, disconnect the tank and do not use the 

appliance until repairs can be made. 

TO LIGHT

 

TIPS: 

Before Beginning    

 Read and understand the instructions  thoroughly. 

 

 Check and make sure that all parts are present. 

 For future reference,  save this instruction  sheet. 

 

 

 

 

 

 

CAUTION

 

If the burner does not ignite with the burner control valve open, gas will continue  to flow out of the burner and could 

accidentally ignite causing injury or property damage.

 

 

USING A LONG MATCH OR LIGHTER

 

 

1 Connect 

propane 

(LP) 

cylinder 

(see 

above 

pages). 

2  Before lighting, move the lava rocks with a small shovel to allow access to the burner. 

WARNING:  Lava rocks can become very hot. DO NOT touch unless they are completely cooled. 

3  Locate the burner control knob and make sure it is in the "OFF" position. 

 

1.

open the cylinder valve.

2.

ignite the fuel.

3.

   then repeat the lighting procedure as above.

4.

   raise the fame. Observe fame height when lit; fame should be a yellow/blue color between 2 inch to 10 inches high.

depending on whether you want to lower or 

Always check burner flames periodically to ensure proper operation. Flames should be mostly yellow with some blue for 

5.

 bestperformance. (See diagram)

Summary of Contents for 66637

Page 1: ...nt alteration service or maintenance can cause injury or property damage Read the owners manual thoroughly before installing or servicing this equipment If the information in this manual is not follow...

Page 2: ...pervised and kept at a safe distance while the appliance is in use Children and adults should be alerted to the hazards of high surface temperatures and keep a safe distance to avoid burns or clothing...

Page 3: ...gas product Propane Characteristics Flammable explosive under pressure heavier than air and settles in pools in low areas In its natural state propane has no odor For your safety an odorant has been...

Page 4: ...used Be sure to use only one 20 lb 9 1 kg LP gas cylinder with a Type 1 valve with this appliance as required by the American National Standards Institute ANSI and the Canadian Standards Steering Com...

Page 5: ...K USE 1 Do not light or use gas unit if lava rocks are wet Ensure lava rocks are completely dry before lighting as intense heat could cause the lava rocks to crack 2 Lava rocks could hit somebody face...

Page 6: ...0KG B C BA 1PC D E TANK SEAT 1PC F PVC COVER 1PC G H I F A D C A 2 BOX C B D E F 1 PC G 1 PC H I 1 PACKAGE B H I J 6 1 PC 2 FIREPIT TABLE 1PC FRONT ENCLOSURE 1PC LEFT ENCLOSURE 2PC LEG 4PC HARDWARE 1...

Page 7: ...this owner s manual for future reference supply system is turned off before assembling bracket and 2pcs M4 x 8 screws 4pcs nut M6 nut and 8pcs washer ASSEMBLY INSTRUCTIONS If you have opened the carto...

Page 8: ...valve and tighten the black coupling nut by turning it clockwise with one hand while holding the regulator with the other hand See diagram Hand tighten only To Disconnect 1 Always confirm that the cy...

Page 9: ...e tank and do not use the appliance until repairs can be made TO LIGHT TIPS Before Beginning Read and understand the instructions thoroughly Check and make sure that all parts are present For future r...

Page 10: ...position 2 Close the LP tank valve 3 Disconnect the regulator from the LP tank to close the gas supply when not in use 4 Make sure that the unit is completely cooled before touching any of the compone...

Page 11: ...ace Sudden drop in gas flow Excess flow safety valve has been activated Turn the control knob to OFF Close the LP tank valve and disconnect the regulator from the tank Turn the control knob to HIGH Wa...