![BOND MANUFACTURING 66637 Owner'S Manual Download Page 11](http://html1.mh-extra.com/html/bond-manufacturing/66637/66637_owners-manual_2786721011.webp)
No gas flow
Check if gas cylinder is empty. If yes, replace.
Regulator is not fully
connected to the tank
Check LP tank connection.
Gas flow is obstructed
Check hose for bends or kinks
Spider webs or insect nest
in the venturi (end of
burner tube)
Clean the venturi
Burner will not light using a match
Burner ports are clogged
Insert an opened paperclip into each of the burner ports to clean
them. Ensure the appliance is off and all parts are cooled before
attempting to clean the burner ports
Flame is obstructed at
burner ports
Make sure all the gas burner ports are free of any lava rocks or
debris to allow the gas to flow freely.
Appliance emits a lot of black smoke
when lit
Regulator hose is pinched
Check the regulator hose for bends or kinks
No gas flow
Check if gas cylinder is empty. If yes, replace.
Sudden drop in gas flow
Excess flow safety valve
has been activated
Turn the control knob to "OFF", Close the LP tank valve and
disconnect the regulator from the tank. Turn the control knob to
"HIGH". Wait 1 minute. Turner the control knob to "OFF".
Reconnect regulator to LP tank. Open tank valve slowly. Light
appliance as indicated in "To Light" section.
High or gusting winds
Increase flame to "High"
No gas flow
Check if gas cylinder is empty. If yes, replace.
Flame blow out
Excess flow safety valve
has been activated
See "Sudden drop in gas flow" above
Irregular flame pattern or flame does not
come out of the entire length of the burner
Burner ports are clogged
See "Burner will not light using a match" above.