BOND MANUFACTURING 66637 Owner'S Manual Download Page 4

• 

The LP gas tank should not be dropped or handled roughly. 

• 

Tanks  must be stored  outdoors  out of the reach of children.  Do NOT store in a building,  garage,  or any other enclosed  area. 

• 

Never store your LP gas tank where temperatures  can reach over 125°F. 

• 

Never keep a filled LP gas tank in a hot car or car trunk. Heat will cause the gas pressure to increase, which may open the relief 

valve and allow gas to escape. 

• 

Place dust cap on valve outlet whenever  the LP gas tank is not in use. Only install the type of dust cap on the LP gas tank valve 

outlet that is provided with the LP gas tank valve. Other types of caps or plugs may result in leakage of propane. 

• 

Do not store a spare LP gas tank under or near this gas appliance. 

• Never 

fill 

the 

tank 

beyond 

80 

percent 

full. 

• 

LP gas cylinders should only be filled by a certified LP gas dealer. 

• 

The pressure regulator is set for 11 inches of water column (pressure). 

• 

The maximum  inlet gas pressure for this outdoor  appliance  is 14 inches of water column  pressure. 

•  Any guard or other protective device removed for servicing the appliance must be replaced prior to operating the appliance. 

•  Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least 

annually by a qualified service person. More frequent cleaning may be required as necessary. It is imperative that control 
compartment,  burners and circulating air passageways  of the appliance be kept clean. 

 

•  The appliance should be inspected before use and at least annually by a qualified service person. 

• 

Do not attempt to disconnect the gas regulator from the tank or any gas fitting while the outdoor appliance is in use. 

•  Keep gas appliance away from location where it can get excessively wet. Do not use gas appliance if any part has been underwater.  

Immediately  call a qualified  service technician  to inspect the appliance  and to replace any part of the control system and any gas 
control which has been under water. 

•  This appliance shall be used only outdoors in a well-ventilated space and shall not be used in a building, garage or any other 

enclosed area. 

•  The LP-gas supply cylinder must be disconnected  when this appliance is not in use 

• Only 

cylinder 

marked 

“propane” 

shall 

be 

used. 

• 

Be sure to use only one 20 lb (9.1 kg) LP gas cylinder  with a Type 1 valve with this appliance  as required  by the American 

National Standards Institute (ANSI) and the Canadian Standards Steering Committee. 

 

• 

LP gas cylinder must contain a shut-off valve as specified in the Standard for Compressed  Gas Cylinder Valve Outlet and Inlet 

Connection, ANSI/CGA-V-1-1977,  CSA B96. 

 

•  Never attempt to attach this appliance to the self-contained  LP gas system of a camper trailer, motor home or house. 

• 

Hand turn the manual gas control valve. Never use tools. If the valve will not turn by hand, do not try to repair it. Call a Certified 

Gas Technician.  The use of force or any self attempted  repair may result in a fire or explosion. 

 

• 

WARNING: 

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to 

the owner’s information  manual provided with this appliance. For assistance or additional information  consult a qualified 
installer, service agency or the gas supplier. 

 

LP Hose and Regulator  Assembly  and Replacement

 

1  This appliance  comes equipped with a standard LP gas hose and regulator including the appliance side connection  for a CGA No 

791 Cylinder Connection  Device. The LP gas hose and regulator supplied with this appliance must be used. Only a hose and 

regulator specified by manufacturer can be used for replacement. 

a) The CGA No 791 connection incorporates  an excess flow limiting device that acts to limit the flow of gas if a leak is detected 

between the regulator and the burner valve. 

 

b) If the burner valve is open prior to the LP gas cylinder service valve being opened, the connection  will interpret this free flow of 

gas to be a leak 

c)  The connection  safety feature will reduce gas flow from the regulator to the appliance to a minimal level. 

d) Be sure that the burner control valve is closed prior to opening the LP gas cylinder service valve to ensure that the connection 

flow limiting device is not triggered  mistakenly. 

e)  If the connection  flow limiting device is triggered mistakenly,  close the LP gas cylinder service valve and the burner valve, wait 

10 seconds to allow the device to reset, open the cylinder service valve, then open the burner. 

valve and light the appliance as per lighting instructions. 

2  Be sure to protect the hose from any hot surfaces. Serious danger may result if the hose contacts any hot surface. 

3 Regular 

maintenance 

of 

the 

hose 

and 

regulator: 

 

 

Summary of Contents for 66637

Page 1: ...nt alteration service or maintenance can cause injury or property damage Read the owners manual thoroughly before installing or servicing this equipment If the information in this manual is not follow...

Page 2: ...pervised and kept at a safe distance while the appliance is in use Children and adults should be alerted to the hazards of high surface temperatures and keep a safe distance to avoid burns or clothing...

Page 3: ...gas product Propane Characteristics Flammable explosive under pressure heavier than air and settles in pools in low areas In its natural state propane has no odor For your safety an odorant has been...

Page 4: ...used Be sure to use only one 20 lb 9 1 kg LP gas cylinder with a Type 1 valve with this appliance as required by the American National Standards Institute ANSI and the Canadian Standards Steering Com...

Page 5: ...K USE 1 Do not light or use gas unit if lava rocks are wet Ensure lava rocks are completely dry before lighting as intense heat could cause the lava rocks to crack 2 Lava rocks could hit somebody face...

Page 6: ...0KG B C BA 1PC D E TANK SEAT 1PC F PVC COVER 1PC G H I F A D C A 2 BOX C B D E F 1 PC G 1 PC H I 1 PACKAGE B H I J 6 1 PC 2 FIREPIT TABLE 1PC FRONT ENCLOSURE 1PC LEFT ENCLOSURE 2PC LEG 4PC HARDWARE 1...

Page 7: ...this owner s manual for future reference supply system is turned off before assembling bracket and 2pcs M4 x 8 screws 4pcs nut M6 nut and 8pcs washer ASSEMBLY INSTRUCTIONS If you have opened the carto...

Page 8: ...valve and tighten the black coupling nut by turning it clockwise with one hand while holding the regulator with the other hand See diagram Hand tighten only To Disconnect 1 Always confirm that the cy...

Page 9: ...e tank and do not use the appliance until repairs can be made TO LIGHT TIPS Before Beginning Read and understand the instructions thoroughly Check and make sure that all parts are present For future r...

Page 10: ...position 2 Close the LP tank valve 3 Disconnect the regulator from the LP tank to close the gas supply when not in use 4 Make sure that the unit is completely cooled before touching any of the compone...

Page 11: ...ace Sudden drop in gas flow Excess flow safety valve has been activated Turn the control knob to OFF Close the LP tank valve and disconnect the regulator from the tank Turn the control knob to HIGH Wa...