Manual
BONA DCS25 Vacuum Cleaner
22
BONA AB
IMPORTANT!
The machine must not be connected
to the power supply during service
and cleaning.
Cleaning and Maintenance
The machine must always be emptied after use. If the
machine is left with dust, there is a risk of self-ignition.
Read the chapter about safety precautions before cleaning and maintenance.
The easiest way to clean the machine is as follows:
•
The Pre-filter is cleaned as required.
•
Wipe the machine on the outside with a dry or damp cloth.
Maintenance of the Motor Top
The motor top is made of maintenance-free parts and therefore needs no daily maintenance, apart from external
cleaning and check that the cords and plugs are undamaged.
The easiest way to clean the motor top is with a damp cloth. Do not aim jets of water directly at the motor top.
In order to avoid stop in operation and also to make sure that the safety of the vacuum cleaner is intact, it is
recommended that the electrical parts are inspected annually by an authorized technician.
It is recommended to have an authorized service centre inspect the motor bushings of the brushes after approx.
800 working hours, and if necessary, replace them. In this way the life of the suction motor is prolonged.
If the brushes are not replaced before being completely worn out, the motor may seize up, and this may require a
replacement of the motor.
Check / maintenance of the machine
Description
Before/After use
Month / year Hours
Replace motor
750-800
Check of HEPA filter and machine
yearly
Emptying and cleaning
After use (as required)
Check of filters and machine, generally
Before use
Check of cord, plugs and outlet for tools
Before use
Check of alarm (beeper)
Before use
Remember to reorder service parts.