1. GENERAL

Carefully read the following important information 

regarding installation safety and maintenance. 

Keep this information booklet accessible for further 

consultations.

CONTROL PANEL

 

(Fig.2)

TYPE “A”

- Pilot light

- Fan-off

- First speed (minimum)

- Second speed (medium)

- Third speed (maximum)

- Light ON/OFF

TYPE “B”

0

 -  Light OFF

1

 -  Light ON

3

   -  Third speed (maximum)

2

   -  Second speed (medium)

1

 -  First speed (minimum)

0  

- Fan-off

2. INSTALLATION INSTRUCTIONS

This hood has been arranged to be installed above a 

cook top. It can be used in 2 ways:

 

EXHAUST MODE

: the kitchen vapours are purified by 

the metal anti-grease filters and carried outside through 

a ducting system. 

(Fig. 3A; 3B)

 

RECIRCULATING MODE

: the kitchen vapours are 

purified by the metal anti-grease filters and an activated 

carbon filter (sold separately), then conveyed back into 

the kitchen. 

(Fig. 3C)

We suggest to have installation carried out by 

qualified personnel, in compliance with all the 

current regulations and in particular with the ones 

concerning air exhaust and electrical connection.

The manufacturer cannot be held liable for damages 

caused by improper installation or if it has not been 

carried out according to the state-of-the-art.

2.1 ELECTRIC CONNECTION

The appliance has been manufactured as a class II, 

therefore no earth cable is necessary.

The connection to the mains is carried out as follows:

BROWN = 

L

 line

BLUE = 

N

 neutral

If not provided, connect a plug for the electrical load 

indicated on the description label. Where a plug is 

provided, the cooker hood must be installed in order 

that the plug is easily accessible.

An omnipolar switch with a minimum aperture of 

3 mm between contacts, in line with the electrical 

load and local standards, must be placed between 

the appliance and the network in the case of direct 

connection to the electrical network.

2.2. INSTALLATION

The appliance must be installed at a minimum height of 

650 mm from an electric cooker stove, or 750 mm from 

gas or combined cooker stoves. (Fig.1)

If a connection tube composed of two parts is used, the 

upper part must be placed outside the lower part. 

Do not connect the cooker hood exhaust to the same 

conductor used to circulate hot air or for evacuating 

fumes from other appliances generated by other than 

an electrical source.

2.3. MOUNTING THE COOKER HOOD TO THE WALL

Drill holes 

A

-

B

-

C

 according to indications quoted in 

(fig.1).

Use screws and screw anchors suitable for wall (e.g. 

reinforced cement, plasterboard) for the mounting of 

the cooker hood. Where screws and screw anchors 

are supplied ensure that they are suitable  for the type 

of wall where the cooker hood is to be mounted.

Affix the bracket 

Z

 to the wall via the drill holes 

C

Hang the cooker hood on the wall using the drill holes 

A

.

Fasten the cooker hood using the fastening drill holes 

B

.

2.4. EXHAUST VERSION

Connect the flange 

Y

 to the discharge opening with 

a  connecting  tube  Fig.5  (do  not  carry  out  for  filter 

version) .

Thread the upper connector 

E

 to the inside of the 

lower connector 

F

; hang the two connectors inserting 

them vertically on the cooker hood, unthread the 

upper connector 

E

 towards the top, locking it in with 

the appropriate screws in the drill holes 

G

 of the 

bracket 

Z

 (fig. 7) previously affixed to the wall via the 

drill holes 

C

 (fig. 1).

2.5 RE-CIRCULATING VERSION

In order to transform your cooker hood from the 

exhaust version to the re-circulating version, ask your 

local  retailer  for  active  carbon  filters  and  then  carry 

out the following instructions.

The filters must be applied to the suction kit located 

inside  the  cooker  hood  (fig.  6).  The  air  is  replaced 

in the environment via the eyelets impressed on the 

connector 

E

.

2.6. OPERATING CHECKS

Check lights and motor start-up on all speeds.

USE AND MAINTENANCE

 

It is recommended to switch on the appliance before 

cooking. It is also recommended to leave the appliance 

in operation for 10 minutes after cooking is terminated 

in order to completely eliminate cooking vapours and 

EN

 

 

 Use and maintenance instructions 

Summary of Contents for BOCP429E

Page 1: ...1 3LIOC2BO Use and maintenance instructions ES Instrucciones de uso y mantenimiento Istruzioni d uso e manutenzione CHIMNEY COOKER HOOD C Instructions pour l utilisation et manutention IT FR EN...

Page 2: ...E roof venting VACUATION EXTERNE ventilation au toit EXTRACCI N ventilaci n para el techo ASPIRANTE uscita soffitto RECIRCULATING MODE RECIRCULATION INTERNE MODALIDAD RECIRCULATION MODALITA FILTRANTE...

Page 3: ...3 3LIOC2BO Fig 5 Fig 4 Fig 7 Fig 6...

Page 4: ...re tra l apparecchio e la rete un interruttore omnipolare con apertura minima tra i contatti 3 mm dimensionato al carico e rispondente alle norme vigenti 2 2 AVVERTENZE PER L INSTALLAZIONE L apparecch...

Page 5: ...ed esclusivamente un panno umido e detersivo liquido neutro Evitare panni e spugne bagnate getti d acqua diluenti solventi alcol e sostanze abrasive 4 AVVERTENZE PER LA SICUREZZA Fare attenzione se fu...

Page 6: ...6 3LIOC2BO Per Assistenza Tecnica Autorizzata e Ricambi Originali rivolgersi al numero unico...

Page 7: ...7 3LIOC2BO...

Page 8: ...650 mm from an electric cooker stove or 750 mm from gas or combined cooker stoves Fig 1 If a connection tube composed of two parts is used the upper part must be placed outside the lower part Do not c...

Page 9: ...rgent 4 SAFETY PRECAUTIONS Take care when the cooker hood is operating simultaneously with an open fireplace or burner that depend on the air in the environment and are supplied by other than electric...

Page 10: ...l et le r seau un interrupteur omnipolaire avec une ouverture minimale entre les contacts de 3 mm proportionnel la charge et correspondant aux normes en vigueur 2 2 CONSEILS POUR L INSTALLATION L appa...

Page 11: ...ans la m me pi ce vous utilisez simultan ment la hotte vacuation avec un br leur ou une chemin e aliment s par une nergie autre que l lectricit vous pouvez cr er un probl me d inversion de flux Dans c...

Page 12: ...n caso de conexi n directa a la corriente el ctrica es necesario interponer entre el aparato y la red un interruptor omnipolar con abertura m nima de 3 mm adecuado a la carga y que responda a las norm...

Page 13: ...etilico o detergentes l quidos neutros no abrasivos SUGERENCIAS PARA LA SEGURIDAD Preste atenci n si funcionan contempor neamente una campana aspirante y un quemador o una chimenea que toman el aire d...

Page 14: ...14 3LIOC2BO...

Page 15: ...15 3LIOC2BO...

Page 16: ...16 3LIOC2BO...

Reviews: