18
USB Commands and Messages
Commands
KA<cr> : keeps USB connection alive
VER<cr> : query firmware version
STATUS<cr> : display status message with LTS-3 installed
RESET<cr> : resets LD-350
DEFAULTS<cr> : restores LD-350 to factory default settings
FT<cr> : sends a forced trigger signal to LD-350
RAW<cr> : query raw data state
RAW <0,1><cr> : disable (0) or enable (1) raw data to be sent through USB
NB<cr> : query noise beep state
NB<0,1><cr> : disable (0) or enable (1) noise beeps when signal is detected
SQ<cr> : query squelch level
SQ<value 0-100><cr> : set squelch level
CAD<cr> : query close alarm distance
CAD<distance 0-250><cr> : set close alarm distance
SAR<cr> : query severe alarm rate
SAR<0-999><cr> : set severe alarm rate
SAVE<cr> : saves current configuration to LD-350
READ<cr> : reads current LD-350 configuration
Appendix
A
Summary of Contents for LD-350
Page 4: ......
Page 6: ......
Page 15: ...10 ANT 2 shown with pole mount installation ANT 2 shown with tripod installation ...