12
OPERATION CONTINUED
• Be sure the battery leads are properly connected and are not damaged or obstructed.
• Reduce the load to the speci
fi
ed generator rated output if the DC protector turns off. If it
turns off again, consult the authorized dealer.
NOTE:
•
If a short or overdraw should occur in the system, it will cause the DC Protector to trip. Press to reset
the DC protector.
NOTE:
• At full charge, electrolyte speci
fi
c gravity is between 1.26 and 1.28
• Check speci
fi
c gravity hourly.
Never smoke near the battery while charging. Do not make or break connections while the
battery is charging. This may cause sparks to ignite the battery gas. Battery acid is poisonous
and dangerous; it contains sulfuric acid. Avoid contact with skin, eyes, and clothing as it will
cause severe burns.
If contact occurs:
EXTERNAL – Flush with water.
INTERNAL – Drink large quantities of water or milk, then drink milk of magnesia, beaten
egg or vegetable oil. Call physician immediately.
EYES – Flush with water for 15 minutes and get prompt medical attention.
Batteries produce explosive gases. Keep sparks, fl ame, cigarettes, etc., away from the generator.
Ventilate when charging or using in closed space. Always wear eye protection when working near
batteries. KEEP OUT OF REACH OF CHILDREN.
STOPPING THE ENGINE
NOTE:
1. Disconnect any electric devices.
2. Turn the engine switch to the “STOP” position.
3. Turn the fuel lever to “OFF”
CAUTION
WARNING
1.
STOP
ON
OFF
2.
3.