background image

 

2.2.6

 

Extreme Situation Actions 

3

 

Maintenance 

3.1

 

General 

The  product  is  to  be  maintained  according  to  a  planned  preventive  strategy  which  provides 

annual scheduled maintenance. 

3.2

 

Safety Precautions 

The detector should be maintained by personnel qualified for the Accident Prevention Level of 

II or higher. 

3.3

 

Maintenance Procedures 

Scheduled maintenance works include: 

 

Visual checking of the interface converter conditions; 

 

Checking conditions of external installation wires and contact joints; 

 

Checking operability as per Clause 3.4 of this manual. 

3.4

 

Performance Testing 

3.4.1

 

Testing operation capability of the interface converter as part of an S2000M panel is testing the 

panel  for  stable  communications  with  a  personal  computer  using  PProg  utility.  Put  the  panel  to  the 
programming mode, and then conduct reading / writing the S2000M configuration. 
3.4.2

 

Indicator’s illuminating means receiving / transmitting signals over the RS-232 interface line. 

3.5

 

Technical Examination 

Technical examination is not applicable for this equipment. 

3.6

 

Preservation (Depreservation, Represervation) 

Preservation is not applicable for this equipment. 

4

 

Repair 

4.1

 

Repair of faulty equipment is to be conducted by the manufacturer or in authorized repair centers.

 

The equipment shall be sent for repair in line with established procedures. 

4.2

 

An equipment fault resulted from consumer’s not observing rules of mounting and operation is not 

a reason for claims and warranty repair. 
4.3

 

Claims shall be submitted to the following address:  
NVP BOLID, #4 Pionerskaya Str., Korolyov, Moscow Region, 141070, Russia 
Tel./fax: +7 (495) 775-71-55 (PBX), Email: 

[email protected]

.  

4.4

 

In  case  of  any  issue  related  to  use  of  the  product,  please  contact  the  technical  support:  +7  (495) 

775-71-55 or e-mail: 

[email protected]

 

Warning! 

If  sparks,  fire,  smoke,  and / or  smell  of  burning  are  found  at  the  installation  site  of  the 
device, the device must be de-energized and sent for repair 

 

WARNING! 

Removing  the  device’s  PC  board  from  its  housing  automatically  voids  the 
manufacturer’s warranty 

 

Attention! 

The  equipment  shall  be  submitted  for  repair  being  assembled  and  clean  and  along 
with all the parts listed in the documentation. 
Claims  are  accepted  only  if  a  reclamation  report  describing  the  failure  is  applied  to 
the submitted equipment. 

Summary of Contents for USB-RS232

Page 1: ...INTERFACE CONVERTER USB RS232 USER S MANUAL ...

Page 2: ...ns 6 2 2 Preparing for Use 6 2 2 1 Safety Precautions 6 2 2 2 Design 6 2 2 3 Mounting 6 2 2 4 Connecting to the PC 7 2 2 5 Testing Operability 8 2 2 6 Extreme Situation Actions 9 3 Maintenance 9 3 1 General 9 3 2 Safety Precautions 9 3 3 Maintenance Procedures 9 3 4 Performance Testing 9 3 5 Technical Examination 9 3 6 Preservation Depreservation Represervation 9 4 Repair 9 5 Storage 10 6 Transpor...

Page 3: ...rface Converter Only the personnel who have studied this manual are allowed to operation activities All activities on mounting programming and commissioning shall be performed in compliance with the requirements of the regulatory documentation in force at the place of operation ...

Page 4: ... a PC 1 2 2 Consumed current mA 200 max 1 2 3 Baud Rates bit s 110 300 1200 2400 4800 9600 19200 38400 57600 115200 1 2 4 Operating temperature range С Minus 30 to 50 1 2 5 Relative humidity Up to 95 at 40 С 1 2 6 RFI caused by the equipment as per GOST R 50009 2000 Not exceed 1 2 7 Weight gram 11 1 2 8 Overall dimensions mm 19 67 11 max 1 2 9 Enclosure protection degree IP20 1 2 10 Non stop opera...

Page 5: ...s The design of the interface converter doesn t provide its operation in aggressive and dusty environments or in ex hazardous premises 2 2 Preparing for Use 2 2 1 Safety Precautions The design of the interface converter meets the requirements of electric and fire safety including emergency operation in accordance with Russian standards GOST 12 2 007 0 75 and GOST 12 1 004 91 There are no potential...

Page 6: ...hould install its driver can be found at the company site http bolid ru in the section PRODUCTS on the page of the USB RS232 interface converter Unpack CP210x_VCP_Windows zip and run the driver installation file that relates to the current operating system bitness CP210xVCPInstaller_x86 exe for a 32 bit system or CP210xVCPInstaller_x64 exe for a 64 bit system The Installer window appearing click N...

Page 7: ...on and device being ready for operation Upon installation of the interface converter driver the group Ports COM LPT of the Device Manager shall contain the entry CP2104 USB to UART Bridge COM x where x is the number of the virtual COM port 2 2 4 5 After the necessary connections are carries out connect the interface converter to the RS232 interface bus via the removable terminal block 2 2 5 Testin...

Page 8: ...nt 3 6 Preservation Depreservation Represervation Preservation is not applicable for this equipment 4 Repair 4 1 Repair of faulty equipment is to be conducted by the manufacturer or in authorized repair centers The equipment shall be sent for repair in line with established procedures 4 2 An equipment fault resulted from consumer s not observing rules of mounting and operation is not a reason for ...

Page 9: ...rements stated in the manuals if the user follows the instructions for transportation storage installation and usage 8 2 The warranty period is 18 months since putting the product into operation but no more than 24 months from the manufacturer s date of production 9 Certification Information 9 1 The USB RS232 interface converter meets the requirements of the Technical Regulations TR CU 020 2011 an...

Reviews: