The screw terminal block provides connecting wires with 0.13 to 0.82 mm

2

 cross section. 

Connection lines are to be erected in line with the schematic shown in Figure 2.2. 
 
 
 
 

 

 

Figure 2.2

 How to Connect USB-RS232 to an S2000M Panel 

 

2.2.4

 

Connecting to the PC 

2.2.4.1

 

Prior to connecting the interface converter to a PC, you should install its driver (can be 

found  at  the  company  site 

http://bolid.ru

  in  the  section  PRODUCTS  on  the  page  of  the  USB–RS232 

interface  converter).  Unpack  CP210x_VCP_Windows.zip  and  run  the  driver  installation  file  that 
relates  to  the  current  operating  system  bitness:  CP210xVCPInstaller_x86.exe  for  a  32-bit  system  or 
CP210xVCPInstaller_x64.exe for a 64-bit system. The Installer window appearing, click Next:  

 

 

2.2.4.2

 

In the next Installer window select the option “I accept this agreement” and click Next:

 

 

GND

TxD 

DTR

S2000

М

 

No…………….. 

Summary of Contents for USB-RS232

Page 1: ...INTERFACE CONVERTER USB RS232 USER S MANUAL ...

Page 2: ...ns 6 2 2 Preparing for Use 6 2 2 1 Safety Precautions 6 2 2 2 Design 6 2 2 3 Mounting 6 2 2 4 Connecting to the PC 7 2 2 5 Testing Operability 8 2 2 6 Extreme Situation Actions 9 3 Maintenance 9 3 1 General 9 3 2 Safety Precautions 9 3 3 Maintenance Procedures 9 3 4 Performance Testing 9 3 5 Technical Examination 9 3 6 Preservation Depreservation Represervation 9 4 Repair 9 5 Storage 10 6 Transpor...

Page 3: ...rface Converter Only the personnel who have studied this manual are allowed to operation activities All activities on mounting programming and commissioning shall be performed in compliance with the requirements of the regulatory documentation in force at the place of operation ...

Page 4: ... a PC 1 2 2 Consumed current mA 200 max 1 2 3 Baud Rates bit s 110 300 1200 2400 4800 9600 19200 38400 57600 115200 1 2 4 Operating temperature range С Minus 30 to 50 1 2 5 Relative humidity Up to 95 at 40 С 1 2 6 RFI caused by the equipment as per GOST R 50009 2000 Not exceed 1 2 7 Weight gram 11 1 2 8 Overall dimensions mm 19 67 11 max 1 2 9 Enclosure protection degree IP20 1 2 10 Non stop opera...

Page 5: ...s The design of the interface converter doesn t provide its operation in aggressive and dusty environments or in ex hazardous premises 2 2 Preparing for Use 2 2 1 Safety Precautions The design of the interface converter meets the requirements of electric and fire safety including emergency operation in accordance with Russian standards GOST 12 2 007 0 75 and GOST 12 1 004 91 There are no potential...

Page 6: ...hould install its driver can be found at the company site http bolid ru in the section PRODUCTS on the page of the USB RS232 interface converter Unpack CP210x_VCP_Windows zip and run the driver installation file that relates to the current operating system bitness CP210xVCPInstaller_x86 exe for a 32 bit system or CP210xVCPInstaller_x64 exe for a 64 bit system The Installer window appearing click N...

Page 7: ...on and device being ready for operation Upon installation of the interface converter driver the group Ports COM LPT of the Device Manager shall contain the entry CP2104 USB to UART Bridge COM x where x is the number of the virtual COM port 2 2 4 5 After the necessary connections are carries out connect the interface converter to the RS232 interface bus via the removable terminal block 2 2 5 Testin...

Page 8: ...nt 3 6 Preservation Depreservation Represervation Preservation is not applicable for this equipment 4 Repair 4 1 Repair of faulty equipment is to be conducted by the manufacturer or in authorized repair centers The equipment shall be sent for repair in line with established procedures 4 2 An equipment fault resulted from consumer s not observing rules of mounting and operation is not a reason for ...

Page 9: ...rements stated in the manuals if the user follows the instructions for transportation storage installation and usage 8 2 The warranty period is 18 months since putting the product into operation but no more than 24 months from the manufacturer s date of production 9 Certification Information 9 1 The USB RS232 interface converter meets the requirements of the Technical Regulations TR CU 020 2011 an...

Reviews: