User Manual
20 of 23
SETUP MENU
Control
Front LED
- Front LED on/off/off after 15s
Local Enable
-Power, up and down key is only worked, if Local enable is off.
IR Enable
- Select the controller of local or remote. If remote controller is
selected, both local (front key) and remote are worked.
However select local, local key only operated.
Auto Key Lock
- If it does not work 10 minutes to lock automatically. Key button is operated after being pressed about 2
seconds
Source Key (Front
“Input” Button/ Remote Controller “Source” Button)
-Menu: Select the input signals to the input menu OSD.
-Rotate: Press Button to rotate the input source.
Communication
ID (01~99)
- If control each Board, must set ID numbers of each Board
Serial Rate _ 422 Baud Rate
- 2400/4800/9600/19200/38400/57600/115200
IP Protocol
- Remcon / TSL 4.0, /TSL 5.0
422 Protocol
-
Remcon / TSL 4.0 / RDU
IP Config
ID
-Network ID
Character Select
DHCP
-DHCP on/off (Manual IP settings
– DHCP on)
* “Apply” enter all settings after.
Fan Control
Fan Control
- Internal Fan Controls driving option by temperature sensor
Auto
/ force
on
/ force
off
Active Temp
- Adjusts fan driving temperature by Celsius degree. It works
only when the Fan Control setting is Auto.
Hysteresis
- Adjusts fan driving hysteresis temperature by Celsius degree. (1~10
℃
)
Shutdown
- For a monitor protection is above of 85
℃
, Power Off.