background image

IMPORTANT! INSTALLER PLEASE NOTE

 Wall mounting structure must be capable of supporting 300 lb. load on fountain.

This fountain is to be mounted on a 

smooth, flat, finished wall surface with 

adequate support structure.

Wall should already be framed for the 

fountain using dimensions shown in 

rough-in’s below. Shown dimensions 

pertain to installation location.

Remove bottom cover from fountain 

and save the screws. Assemble the push 

rod to the fountain. (Push rod provided 

with freeze resistant box)

Install the fountain using bolts and 

washers (not provided). Tighten securely.

Attach drain tube to fountain and cut 

to required length using the freeze 

resistant box as a guide.

Install freeze resistant box - see box 

instructions.

Install a service stop (not provided) and 

make water supply connection from 

the stop to the strainer in the freeze 

resistant box. 

DO NOT SOLDER TUBES INSERTED 

INTO THE STRAINER AS DAMAGE TO 

THE O-RINGS MAY RESULT.

Connect fountain water line to freeze 

resistant box - see box instructions. 

Replace the bottom cover.

1

2

3

4

5

6

7

8

GENERAL INSTALL TIPS

7/16”

11 mm

MOUNTING 

HOLE (3)

12 7/8”

327 mm

3”

76 mm

1 3/4”

44 mm

WASTE LINE

3”

76 mm

3 7/8”

98 mm

2”

51 mm

7/16”

12 mm

5 3/16”

132 mm

29 1/8”

740 mm

29 7/16”

748 mm

1”

25 mm

FOR PUSHROD

7/8”

22 mm

O.D. 

WATER 

INLET

(3)

FINISHED FLOOR

27”

686 mm

13 7/16”

342 mm

15 1/4”

 

387 mm

19 ”

 

482 mm

FREEZE 

RESISTANT 

BOX

35 1/2”

902 mm

WASHER

ACORN NUT

CLOSET SCREW

OR THREADED ROD 

(DEPENDING ON WALL TYPE  

AND ANCHOR USED)

FIGURE 1

 

SUGGESTED CONFIGURATION  

FOR EXPOSED MOUNTING BOLTS

NOTE

 

DFWM-12-FR height is the same as 

DFWM-19-FR

FIGURE 2

34”

864 mm

7 1/4”

 

184 mm

12 7/8”

 

327 mm

DFWM-12-FR 

2

DFWM-12-FR & DFWM-19-FR — Owner’s Manual

3

Bohlmann Quality Products — www.bohlmann.com

DFWM-19-FR 

Summary of Contents for DFWM-12-FR

Page 1: ... wall Refer to the Freeze Resistant Package for the rough in dimensions for installation IMPORTANT ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON IMPORTANT THEGROUNDINGOFELECTRICALEQUIPMENTSUCHASTELEPHONE COMPUTERS ETC TO WATERLINESISACOMMONPROCEDURE THISGROUNDINGMAYBEINTHEBUILDINGORMAY OCCURAWAYFROMTHEBUILDING THISGROUNDINGCANCAUSEELECTRICALFEEDBACKINTO AFOUNTAIN CREATINGANELECTROLYS...

Page 2: ...e stop not provided and make water supply connection from the stop to the strainer in the freeze resistant box DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE O RINGS MAY RESULT Connect fountain water line to freeze resistant box see box instructions Replace the bottom cover 1 2 3 4 5 6 7 8 GENERAL INSTALL TIPS 7 16 11 mm MOUNTING HOLE 3 12 7 8 327 mm 3 76 mm 1 3 4 44 mm WASTE LINE...

Page 3: ...rom the fitting relieve water pressure push in on the gray collar while pulling on the tubing see figure 4 1 4 O D TUBE WATER INLET TO COOLER 3 8 O D UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY NOTE WATER FLOW DIRECTION BUILDING WATER INLET SERVICE STOP NOT FURNISHED 1 25mm APPROXIMATELY STREAM HEIGHT Stream height is factory set at 45 50 PSI If supply pressure varies greatly from this adjust s...

Page 4: ...TION 1 400942308640 Bubbler Dual Stream 2 100322740560 Bubbler Gasket 3 600985551640 Drain Plug Assy 4 170705042830 Basin Receptor 5 15013C Bubbler Tube Assy 6 100147140560 Drain Gasket 7 55884C Drain Elbow 8 55885C Slip Joint Nut 1 1 4 9 66346C Drain Tube 10 97056C Freeze Resistant Box 3 4 2 5 6 7 8 9 2 1 10 ...