TROUBLE SHOOTING & MAINTENANCE
FIGURE 3
FIGURE 4
FIGURE 5
Orifice Assy:
Mineral deposits on orifice can cause water flow
to spurt or not regulate. Mineral deposits may be removed
from the orifice with a small round file or
small diameter wire.
CAUTION: DO NOT file or cut orifice material.
Stream Regulator:
If orifice is clean, regulate flow as in
“STREAM HEIGHT ADJUSTMENT”
instructions below. If
replacement is necessary, see parts list for correct regulator
part number.
Actuation of Quick Connect Water Fittings:
Cooler is
provided with lead-free connectors which utilize an o-ring
water seal. To remove tubing from the fitting, relieve
water pressure, push in on the gray collar while pulling
on the tubing (see figure 4).
1/4” O.D TUBE WATER
INLET TO COOLER
3/8” O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
NOTE:
WATER FLOW DIRECTION
BUILDING WATER INLET
SERVICE STOP
(NOT FURNISHED)
1” (25mm)
APPROXIMATELY
STREAM HEIGHT:
Stream height is factory set at
45-50 PSI. If supply pressure varies
greatly from this, adjust screw on
regulator in freeze resistant box.
Clockwise adjustment will raise
stream and counter-clockwise
adjustment will lower stream. For
best adjustment, stream should hit
basin approx. 6-1/2” from bubbler.
SIMPLY PUSH IN TUBE
TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLECT
TO RELEASE TUBE
PUSHING TUBE IN BEFORE PULLING IT
OUT HELPS TO RELEASE TUBE
A
B
C
2
DFWM-12-FR & DFWM-19-FR — Owner’s Manual
3
Bohlmann Quality Products — www.bohlmann.com