background image

Page   10 

BCMC 3000 Series Master Clock Programming Manual 

50 Spring Street, P.O. Box 575, Ramsey, New Jersey  07446   Tel: 201-934-8500, Fax: 201-934-9832, Web Site: www.bogen.com 

Technician Addresses 

Customer Password 

Address 000:  This address allows the customer password to be modified.  The default value 
is 1111.  This password can be any four (4) characters. 
 

Clock System Selection 

Address 004:  This address controls Clock System #1 (000 is off, default value is 006) 
Address 005:  This address controls Clock System #2 (000 is off, default value is 001) 
 

Clock System On/Off 

Address 006:  This address controls the Clock Systems (000 is off, default value is 001, 002 
allows the user to manually control the power sent to the clock systems) 
 

Send Numeric Message 

Address 007:  This address enables/disables the numeric messaging function.  This function 
can only be used when running a digital clock system (except the BCBL 1000 series).  Nu-
meric messaging allows the customer to send a numeric message to individual clocks, or to a 
group of clocks in the system, or to all the clocks.  To allow for numeric messaging, enter 
“001” to enable this feature.  “000” turns this feature off.  (default value is 000) 
 

Send Bell Message 

Address 008 - 019: 

This address enables/disables the Bell message function.  This function 

can only be used when running a digital clock system (BCBD 1000, BCBZ Zone, or BCBD 
2000 series).  It sends a message to the digital clocks whenever the relay closes to display the 
word “BELL” on the digital clock screen whenever a bell rings.  This function is helpful 
when dealing with a hearing-impaired community.  You can program the master clock to 
send the Bell message to individual clock zones by entering the programmed zone into each 
address.  There are four relays that come standard with each master clock, with an additional 
eight as options.  Addresses 008 through 019 turn on or off this option for each relay/zone in 
the master clock.  Enter “001” to send a bell message to each zone (default value is 255 and 
will disable this function). 
 

Duration Settings For Zones 

Address 020 - 066: 

These addresses allow the user to set the desired duration of the relay 

closure from 1 - 3600 seconds.  Addresses 020 - 034 control the standard four (4) zones.  Ad-
dresses 036 - 066 control the option eight relays that are available.  For example, Address 
020 is Duration 1 for Zone 1 (default value is 3).  Address 022 is Duration 2 for Zone 1 
(default value is 5).  Address 024 is Duration 1 for Zone 2.  Address 026 is Duration 2 for 
Zone 2, etc. 
 
 

Summary of Contents for BCMC 3000 Series

Page 1: ... Page 2 SETTING THE TIME Setting The Time of Day Page 3 SETTING THE DATE Setting the Date Page 4 EVENTS Programming Events Pages 4 5 Editing Events Page 6 SCHEDULE CHANGES Adding Schedule Changes Page 7 Edit Schedule Changes Page 8 ACTIVATE MANUALLY Activate Manually Page 8 ADVANCED OPTIONS Advanced Options Page 9 TECHNICIAN MODE Technician Modes and Addresses Pages 9 12 Table of Contents Page 1 ...

Page 2: ...sts of both a top and a bottom line When the master is powered on the LCD display should read Entering the Password To enter the user programming mode you will need to use the 4 digit User Password provided on page one of this manual The user password will be programmed prior to installation by the contracting company techni cian who is supplying the clock system Press the four digits of the passw...

Page 3: ...ANCEL button on the keypad If the time is correct press the YES ENTER button If the YES ENTER button is button is pressed the display will go to the next option If the NO CANCEL button is pressed the display will read Enter the time that you want into that master clock in 24 hour mode The display will read Press the YES ENTER key Then the prompt will go back to Press the YES ENTER button to advanc...

Page 4: ...the date then the display will read Enter the correct date After entering the correct date in the display will read Press the YES ENTER button The display will read Setting The Date Date OK mm dd yy Enter Date Are you sure mm dd yy Date OK mm dd yy Programming Events The prompt will read If you wish to enter programming press the YES ENTER button If you do not wish to enter programming press the N...

Page 5: ...to the desired day s and press the YES ENTER button The letters will capitalize confirming your selection After making your selection press the arrow A new display will come up and will read To toggle through the zones press the and arrow keys To toggle through the dura tions press the YES ENTER button till the desired choice is made After selecting the options press the arrow key The display will...

Page 6: ...schedule number of where the event is located When the schedule number is en tered a screen will come up that looks like the following Cycle through the events by using the and buttons When the event comes up that you want to edit press the YES ENTER key and the display will come up that looks like the following Follow the instructions on page 5 for programming events If you wish to delete the eve...

Page 7: ...utton to add a schedule change Press the NO CANCEL button to advance to the next option If the user chooses to add a schedule change the display will read Enter the schedule that you wish to change to Then the display will read Enter the time you wish the schedule change to occur Then the display will read Enter the date you wish the schedule change to occur Then the display will read Press the YE...

Page 8: ...the YES ENTER button to edit Follow the instructions on page 7 to set up a schedule change If you wish to delete the schedule change type in 000 over the schedule and accept the changes Edit Schedule Change Sch mm dd yy Edit hh mm ss The display will read Press the YES ENTER button to enter this option Press the NO CANCEL button to leave programming The display will read Scroll through the zones u...

Page 9: ...clock The addresses are as follows Address Description Address Description 000 Customer Password 032 Duration 1 for Zone 4 004 Select clock system 034 Duration 2 for Zone 4 005 Select clock system 036 Duration 1 for Zone 5 006 Clock system on off 038 Duration 2 for Zone 5 007 Enable numeric messaging 040 Duration 1 for Zone 6 008 Send BELL message Zone 1 042 Duration 2 for Zone 6 009 Send BELL mes...

Page 10: ...e off default value is 000 Send Bell Message Address 008 019 This address enables disables the Bell message function This function can only be used when running a digital clock system BCBD 1000 BCBZ Zone or BCBD 2000 series It sends a message to the digital clocks whenever the relay closes to display the word BELL on the digital clock screen whenever a bell rings This function is helpful when deal...

Page 11: ...ed every 10 seconds 004 data transmitted every 15 seconds 005 data transmitted every 30 seconds 006 data transmitted every minute 007 data transmitted every 2 minutes 008 data transmitted every 5 minutes 009 data transmitted every 10 minutes 010 data transmitted every 15 minutes 011 data transmitted every 30 minutes Any other value will turn off RS485 data transmission BIT Testing Address 079 This...

Page 12: ... to test Pressing 1 tests Zones 1 4 Pressing 2 tests Zones 1 8 Pressing 3 tests Zones 1 12 Inputs Press YES to test the inputs Use a jumper to jump pins 5 and 6 The Clk in will flash between 0 and 1 Communication Out The master clock will check the communication output An oscillo scope is needed and you should get a square wave if the communication output is function ing properly Reset Address 080...

Reviews: