Setting Parameters
5.2
Changing Individual Parameters
Page 22
BOGE
base
control for scroll compressors
The start value for the remaining hours can be changed. To
reset / change
the start value of the countdown counter until the next motor servicing interval:
1. Unlock the code-protected parameters for the motor servicing interval
using
code 222
, as described under
"Unlocking Code-protected Param-
.
The current start value for the countdown counter flashes on the seven-
segment display.
2.
Press the Info key
until the desired value is displayed.
3.
Press the Enter key
.
The main display reappears on the control.
The previous value is overwritten.
The changed value is set.
Change Target Pressure
Values (p
max
and p
min
)
This parameter can be used to change the target pressure values.
The p
max
value defines the switch-off pressure of the compressor. If the
network pressure reaches this value during an output phase, the control
switches off the compressor automatically.
The p
min
value defines the switch-on pressure of the compressor. If the
network pressure falls below this value, the control switches the compressor
on automatically.
To change the p
max
and p
min
target pressure values:
1. Unlock the code-protected parameters for the target pressure values using
code 360
, as described under
"Unlocking Code-protected Parameters"
.
The currently valid upper target pressure value (p
max
) flashes in the
seven-segment display.
2.
Press the Info key
until the desired p
max
value is displayed.
3.
Press the Enter key
.
The currently valid lower target pressure value (p
min
) flashes in the
seven-segment display.
The previous p
max
value has been overwritten.
The changed value is set.
4.
Press the Info key
until the desired p
min
value is displayed.
CAUTION
Compressor Damage
If the maximum start value (30,000 h) is set, the countdown counter stops
and the motor servicing interval function is deactivated, meaning that
urgently required servicing work may be overlooked.
Please consult BOGE Product Support prior to setting the highest value.