Installation
Optional added features
The V600 can be configured to suit customer specification. These
optional extras would be discussed, arranged and installed prior to
delivery.
(
If unsure what features your system is equipped with please
contact the seller with the unit serial number,
(Refer to section
2
for location)
who will be able to advise what specification has
been supplied.
Remote Stop/Start feature
Enables the extraction unit to be remotely turned On / Off via an
external signal.
Note: Care must be taken to ensure that the system is correctly
wired in order for the extraction unit to function correctly.
DC Voltage input
This configuration requires the Black & Red cores of the signal
cable (Refer to section
1
for location) to be connected to a known
and tested DC power supply, in order to start the extractor.
The operating voltage for this signal is 24VDC. Only this voltage
should be connected. Voltages connected outside of this range
may cause irreversible damage to the relay.
Red cable = V+
Black cable = V-
When the extractor is provided with the correct DC voltage the
motor will start and maintain the set flow rate (Refer to section
5
for how to set the flow) when the DC voltage is removed the motor
will slow down and come to a stop.
The extractor will need to be turned on (See section
5
for turning
the extractor on) in order for this feature to operate.
Override
Enables the extractor to operate fully with or without either DC
voltage input or the Volt free input.
The override feature can be toggled On / Off by a switch mounted
on the internal motor access panel (see below for switch location)
Switch in “On” position
In this position the extractor will require a start signal (either
Voltage input or Volt free, depending on the requested
specification) to enable the motor within the extraction unit.
Switch in “Off” position
In this position the extractor motor will run without the
requirement for an external start signal. This feature is useful for
engineers carrying out works/ tests on the extractor without the
need for the laser / auxiliary signal being present.
Filter Blocked / System Fail Signal
With this option the extraction system will output a signal to alert
the user when the extractor has failed or when the filters are
blocked.
This feature will not directly stop the extractor from running
correctly, but if fitted this feature should be terminated correctly
before power is applied to the extraction system.
Connection specification
This signal is available via the Green and White cores of the signal
cable. The system will provide a volt free Open / Closed signal that
can be connected to an external interface, beacon or warning
device following the specification below.
•
Maximum input voltage: 24V AC
•
Maximum current load: 3A @ AC
OR
•
Maximum input voltage: 24V DC
•
Maximum input load: 3A @ DC
Filter Signal
When the filters become blocked or the system develops a fault
the connection between the Green & White cables will become
“Open”
When the extraction system is running normally the connection
between the Green & White cables will become “Closed”