1.     Safety

 
  

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
  

 
   

 
 

The following symbols marked on the equipment mean: 

 
Caution: Read these operating instructions fully before use and pay particular 

attention to sections containing this symbol. 

 
Attention: Suivre attentivement les instructions avant l’usage et prêtez une attention 

particulière aux sections comportant ce symbole. 

 
Caution: Surfaces can become hot during use. 
 
Attention: Les surfaces peuvent devenir brûlantes pendent l’usage. 
 
Caution: Risk of electric shock.  Before attempting any service to this unit remove 

power cord from the rear of the unit. 

 
Attention: Risque électrique! Débrancher la prise arrière de réparer l’appareil. 
 

Always observe the following safety precautions: 

 

 

Use only as specified by the operating instructions or the intrinsic protection may 
be impaired.  After transport or storage in humid conditions, dry out the unit 
before connecting it to the supply voltage.  During drying out the intrinsic 
protection may be impaired.  Allow unit to dry out for 4 hours minimum. 

 

Connect only to a power supply with a voltage corresponding to that on the serial 
number label. 

 

Connect only to a power supply that provides a Protective Earth terminal. 

 

Before moving, disconnect at the power supply socket.  Do not remove the plug. 

 

Do not check the temperature by touch, but instead use the temperature display. 

 

To reduce the risk of eye injury during high temperature operation, use safety 
goggles or spectacles. 

 

Do not touch surfaces that become hot during high temperature operation. 

 

To protect from fire and other possible hazards, ensure that the operating 
temperature is less than the maximum operating temperature of your sample 
material. 

 

Ensure that the power switch is easily accessible during use. 

 

If liquid is spilled inside the unit, disconnect it from the power supply and have it 
checked by a competent person. 

 

It is the user’s responsibility to carry out appropriate decontamination if 
hazardous material is spilled on or inside the equipment. 

 

The Power Cord supplied with the unit is the disconnect means. 

 

 
 

Summary of Contents for InSlide Out 241000

Page 1: ...N2400117 Rev 4 01 2013 Boekel InSlide Out Hybridization Oven Models 241000 and 241000 2 Operating Instructions ...

Page 2: ...Lamps see Figure 1 3 4 2 Setting the Temperature 4 4 3 Loading Tray with Slides 4 4 4 Loading Tray into Heating Chamber 4 4 5 Removing Tray from Heating Chamber 5 5 Accessories 5 5 1 Slide Holder 5 6 Fault Diagnosis 6 7 Technical Specifications 6 8 Maintenance and Service 7 8 1 Cleaning 7 8 2 Replacement of Fuses 7 9 Warranty 8 10 Service 8 ...

Page 3: ...ntrinsic protection may be impaired Allow unit to dry out for 4 hours minimum Connect only to a power supply with a voltage corresponding to that on the serial number label Connect only to a power supply that provides a Protective Earth terminal Before moving disconnect at the power supply socket Do not remove the plug Do not check the temperature by touch but instead use the temperature display T...

Page 4: ...ain for future shipment or storage of the unit Inspect for damage Report all shipping damage to the carrier immediately Shipping damage is covered by the carrier and repair replacement for shipping damages must be coordinated through the carrier Complete and return the Warranty Registration Card Packs should contain In Slide Out Hybridization Oven Power Line Cord Operating Instructions Tray Assemb...

Page 5: ...vent of power loss the Temperature Controller retains the last set temperature value 4 3 Loading Tray with Slides The tray with the standard wire rack can be loaded with up to 20 standard glass slides see Figure 2 Using the optional slide holder up to 18 standard glass slides can be loaded see Figure 3 Use your standard protocol to prepare the slides with probe and buffer Place filter paper at the...

Page 6: ...the main door 4 5 Removing Tray from Heating Chamber Extreme care must be used when removing the tray due to the potentially high temperature It may be necessary to use gloves when removing the tray To remove the tray from the Heating Chamber open the main door lift the Latch Handle up and rotate it 180 in a counter clockwise direction Rotate the latch down lift the frame up and carefully slide th...

Page 7: ...re is lower than set temperature b Temperature control circuit fault a Check set temperature b Have unit checked by competent person 4 Slides dry out during heating cycle a Gasket not sealing b Lid bent c Insufficient buffer placed in bottom of tray d Latch not fully engaged a Replace Tray and Gasket Assembly b Replace Lid c Place more buffer in bottom of tray d Re install Tray Assembly into chamb...

Page 8: ...Service All Boekel laboratory products are designed to comply with IEC1010 1 No routine maintenance is required 8 1 Cleaning Disengage power cord prior to cleaning If a spill occurs use appropriate clean up procedures as required for radiation or biohazard control The outer casing may be cleaned with water and a damp cloth Do not submerge or immerse the InSlide Out in water Before using any cleani...

Page 9: ...to these operating instructions Boekel warrants this product to be free of defective material and workmanship for a period of two years from the date of manufacture The liability of Boekel for any defective equipment during the warranty period shall be limited to the repair of such equipment or replacement thereof without charge for parts or labor 10 Service A Returned Goods Authorization RGA numb...

Reviews: