background image

Feb.%2.%2012%

!

HOW!TO!COMPLETE!AN!INCLINE!CALIBRATION!

2012314!TREADMILLS!

Model!#!F9621****!

!

!

 

 
 
WARNING  – 

Do  not  stand  on  the  belt  during  this  procedure.  If  the  incline  calibration  is 

interrupted,  do  not  use  the  treadmill.    It  is  important  to  fully  complete  the  incline  calibration 
procedure again before using the treadmill. 

 

2012 T260P, T280P, T460XC, T520P, T560X 
 

1. Enter the Diagnostics menu by pressing and holding the iTek button for 3 seconds. 
2. You  have  correctly  accessed  the  Diagnostics  menu  when  you  see  DIAGNOSTICS  on 

screen and a scrolling message: “TXXX VERSION”.  

3. Use  the  SPEED  INCREASE  &  DECREASE  keys  to  scroll  through  the  Diagnostics  menu 

until ELEVATION CALBRATION is on screen. 

4. Press the Just Go key twice to begin the Elevation Calibration 
5. Once you see “COMPLETE” on the display, press the “Stop” key 4 times to return to the 

“Welcome Screen”. Your treadmill is ready to go. 

 

2012 T240S, T240S0, T260P, T280S, T280PO, T460XC, T520P, T560X 
 

1. Remove the motor cover. 
2. Locate  the  Incline  Calibration  button  labeled  “INCLINE”.  It  is 

directly below the EPROM and above the LED Display on the 
left side of the board.  (See picture to right.) 

3. Press  and  hold  the  button  down  for  3  seconds.  The  platform 

will  start  elevating.  As  soon  as  the  platform  begins  elevating, 
release the button and the calibration will perform on its own (it 
will last about 1 minute). 

4. When  the  calibration  is  completed,  start  the  unit  and  test  the 

speed and incline function correctly. 

1. Reinstall the motor cover onto the treadmill. 
 

Summary of Contents for T460XC

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ...sor light flashes when you turn the motor but Error 53 still immediately appears when the treadmill is turned on it could be the R64 resistor on the MCB ROM PC Self Check error EPROM is correctly inst...

Page 9: ...se Put Safety Key appears on the Display then check the Reed Switch wiring is connected correctly to the Display If the wiring is connected correctly then check the Reed Switch is in the correct posit...

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ...the connection at the MCB which can get dusty If the connections are OK then most of the time it is a problem with a pinched Data Cable that has damaged one of the two communication wires inside Data...

Page 15: ...an 0 9 or up to 4 ohms If you get OL Overload on the multimeter then you have an open circuit in the motor and will likely have it in every position you try to take a reading The above mentioned Quick...

Page 16: ...then the Speed Sensor LED on the MCB will flash as it takes a reading between each segment of the optic disc 54 The Relay on the MCB is signaling that it is closed when it should be open Defective Rel...

Page 17: ...ace the motor brushes Use a 9V battery to test the motor Remove the Drive Belt that is connected to the Drive Motor Pulley and place the motor wires on the battery terminals the motor should spin The...

Page 18: ...turn the right rear roller screw B counter clockwise to allow the belt to track to the right and towards the centre If the running belt is tracking moving to the right turn the left rear roller screw...

Page 19: ...LEVATION CALBRATION is on screen 4 Press the Just Go key twice to begin the Elevation Calibration 5 Once you see COMPLETE on the display press the Stop key 4 times to return to the Welcome Screen Your...