www.bodine-electric.com
13
Step 10 – Operate the Control
The Model 1865 control is operated using the switch and speed dial on the
front panel of the control. See Figure 8 for panel layout.
1) Turn the AC power ON using the power toggle switch. The power indicator
lamp will illuminate.
2) Adjust speed by turning the speed adjustment dial. Turning the dial fully
CCW will produce the minimum output speed, as set by the MIN trim pot
inside the control. Turning the pot fully CW will produce the maximum output
speed, as set by DIP switch #8 and the MAX trim pot inside the control.
3) To stop the motor, turn the AC power off using the power toggle switch.
4)
If the motor does not start promptly and run smoothly, refer to
the“TROUBLESHOOTING” section.
OFF• AUS• ARRET
SPEED•DREHZAHL•VITESSE
ON•EIN•MARCHE
0
10
20
30
40 50
70
60
80
90
100
TYPE UPM
ADJUSTABLE SPEED
TORQUE CONTROL
Speed
Adjustment
Dial
Power
Indicator
Lamp
Power
Toggle
Switch
FIGURE 8 – Control panel layout