background image

7) CONNECTING A DOUBLE FACE CLOCK

- Open up the 2 clocks by unscrewing the 9 screws (R).

- Pass the connector (HE14) through the grommet (S) on each clock, and connect it to the

male connector (T).

Caution :

1 - Cables for respectively the master clock and the slave clock are not the same : there is a 

specific mark for each of these.

2 - The cables for the master is one meter long. This cable can not be extended as it may

cause a problem with the clock operation mode.

- Close up the clock again.

- Connect the 115 or 230 V 50/60 Hz mains supply (depending on the model) (cf. Chapter 2) 

and whatever the type of master clock, the slave clock wire to the master clock.

7

R

S

T

Slave clock

Female DIN

connector

Male DIN

connector

Mas ter  clock 

Summary of Contents for Style 12

Page 1: ... B DHF RADIO INSTALLATION AND OPERATING INSTRUCTIONS When receiving goods please chek nothing is broken otherwise make a claim near shipping compagny B P 1 49340 TRÉMENTINES FRANCE Tél 02 41 71 72 00 Fax 02 41 71 72 01 www bodet com Réf 605863 F ...

Page 2: ...ON 1 2 minute series 4 4 RADIO SYNCHRONIZED CLOCK STARTING UP 5 4 1 France Inter or DCF radio synchronised clock 5 4 2 DHF clock 5 4 3 AFNOR IRIG B clock 5 5 CONNECTING A TEMPERATURE PROBE TO A STYLE 12 CLOCK 6 6 CONNECTING A TIMER CONTROL UNIT TO A STYLE 12 S CLOCK6 7 CONNECTING A DOUBLE FACE CLOCK 7 8 CONFIGURATION AND SETTING THE TIME 8 8 1 Configuration menu 8 8 2 Time setting 8 8 3 Reset DHF ...

Page 3: ...s with cable clamps S N B The Style clocks have been designed for a mains power supply of 115 or 230 Volts 10 depending on the model This clock is protected by a 1 25 A 250 V fuse F1 The mains supply unit for this clock must include a 10 A interlocked circuit breaker This circuit breaker has to be switched off in case of maintenance operation E g 230 V clocks will work equally well in countries wh...

Page 4: ...ck time Chapter 8 3 2 INVERTED POLARITY SERIES DISTRIBUTION 1 2 minute series Connect the impulse line to the COM and series terminals on the terminal block D So as to avoid cutting out the network when disconnecting one slave clock also connect the 33 Ohm 1 2 Watt resistance supplied between the COM and series terminals on the terminal block D select the impulse type 1 2 minute and set the clock ...

Page 5: ...with the clock On leaving the factory the DHF clock is set in Initialisation mode On the initial powering up the time is initialised at 0h00 1 jan 2000 The clock memorises the address of the transmitter and switches to normal mode automatically when time is received 4 3 AFNOR IRIG B clock On the initial powering up the time is initialised at 0h00 1 jan 2000 The clock automatically set up its time ...

Page 6: ...S CLOCK The timer control unit reference no 936400 operates both ways to count up and to count down It has the following different functions Start stop intermediate time closing of a contact sharp at the end of count up or countdown to stop on a pre set time The timer control unit can drive up to ten Style 12 S clocks Connect the timer control unit to the terminal block E with a 4 wire cable T T a...

Page 7: ... are not the same there is a specific mark for each of these 2 The cables for the master is one meter long This cable can not be extended as it may cause a problem with the clock operation mode Close up the clock again Connect the 115 or 230 V 50 60 Hz mains supply depending on the model cf Chapter 2 and whatever the type of master clock the slave clock wire to the master clock 7 R S T Slave clock...

Page 8: ...io synchronization Slave Minute on INDEP QUARTZ MIN 1 2 MIN Model Slave 1 2 Minute on INDEP QUARTZ MIN 1 2 MIN Model Slave Afnor Irig B on INDEP QUARTZ MIN AFNOR IRIG B model Note If an antenna has been connected the Ind mode is selected automatically Pressing will have no effect and it is not possible to select Min 1 2 M or Afn 8 2 Time setting In the configuration menu when the selected mode e g...

Page 9: ... calibrate the displayed temperature according to the official temperature Once the adjustment is over press Select key to confirm This last press enables to escape from Setting the time menu after running the self test Switching on all the Leds for 2 seconds Switching off all the Leds for 1 second Return to normal display 8 3 Reset DHF clock to Initialisation mode On leaving the factory the DHF c...

Page 10: ...conds dynamic reception 0 00 displayed the flash as the bits are decoded and then the digits are displayed as they are received After 10 minutes end of the test return to normal display You can exit this test mode by pressing the key Case 3 Antenna recognized recognized antenna type FldC or MSF displayed for 2 seconds dynamic reception 0 00 displayed the flash as the bits are decoded idem LED of t...

Page 11: ...hting conditions 11 DATA BACK UP Style clocks are fitted with a device for storing the configuration parameters even in the event of an extended power failure However the date and time may be lost following a lengthy power failure in excess of 72 hours In this case the clock will display 0 00 when the power supply is restored This occurs notably when the clock is first brought into service Wheneve...

Page 12: ...urs Save other parameters permanent Style 12 inside Style 12 outside Style 12 S inside Style 12 S outside Operating temperature 0 to 50 C 40 to 70 C 0 to 50 C 40 to 70 C Weight wall support 0 6kg 5 kg 5 1 kg 6 4 kg 6 6 kg Maximum nominal current mA Red 40 Yellow 54 Red 70 Yellow 85 Protection IP 51 53 51 53 Consumption VA Red 9 Yellow 12 Red 16 Yellow 19 Style 12 Dimensions Style 12S Dimensions 12...

Reviews: