5) CONNECTING A TEMPERATURE PROBE TO A
STYLE
12 CLOCK
Caution : Style 12S cannot display temperature.
Set up the temperature probe in a well ventilated spot out of
the sun and the rain and at a maximum distance of 50m.
Care should be taken in choosing where to position the
probe in order to ensure that the temperature readings are
correct. Avoid south-facing frontages, metal parts and
draughts.
- Connect the temperature probe to the “TEMP-” and
“TEMP+” terminals on the terminal block (E).
- If the probe is connected the wrong way round, the clock
will display 0°C.
- The probe cannot be submerged.
6) CONNECTING A TIMER CONTROL UNIT TO A
STYLE
12 S CLOCK
The timer control unit reference no. 936400 operates both ways, to count up and to count
down. It has the following different functions : Start, stop, intermediate time, closing of a
contact sharp at the end of count up or countdown (to stop on a pre-set time). The timer
control unit can drive up to ten
Style
12 S clocks.
- Connect the timer control unit to the terminal block (E) with
a 4 wire cable (T-, T+ and 2 wires for 12 V power supply).
- To chain several
Style
12 S clocks to the same timer
control unit, connect the terminals T- and T+ to their
respective terminal blocks (E) with a 2 wire cable (telephone
pair).The first clock is still connected to the timer control unit
with a 4 wire cable.
- For further details, please consult the timer control unit instruction manual ref.: 604821.
6
E
Brown
White
E
BT
Max. 500 m and 10
Style
12S
Maxi 20m