22
BTX6125MS
1/ Open all access hatches.
2/ Connect a communication cable from the BTX6025MS COM board to the BTX6102 COM board (A).
3/ Connect a 240V power cable with the green connector from the BTX6025MS going to the BTX6102
connector (B).
4/ Connect the 240V + earth power supply to the BTX6025MS (E) power supply unit (the power cable
(3x1.5²) is not supplied by BODET)..
BTX6025MS
1/ Connect the 240V + earth power supply to the BTX6025HK (E) power supply unit (the power cable
(3x1,5²) is not supplied by BODET)..
2.4 DIPs settings
Card main panel (BTX6025MS)
On the first DIP bank
On the 1st dip bank, dips 1 to 4 are used for the factory configuration of the panel.
Out of the factory the dips are set as follow:
Dip 1
Dip 2
Dip 3
Dip4
on ↑
on ↑
on ↑
on ↑
Dips 5 to 7 are used to identify each panel (If several panels are used on the same site
each panel must have its own number.).
Dip 8 is not used
.
A
B
C
First DIP bank
Second DIP bank
Panel number
Dip 5
Dip 6
Dip 7
1
off ↓
on ↑
on ↑
2
on ↑
off ↓
on ↑
3
off ↓
off ↓
on ↑
4
on ↑
on ↑
off ↓
5
off ↓
on ↑
off ↓
6
on ↑
off ↓
off ↓