HEC Series
19
Service Procedure I
Thermostat Circuit Testing & Replacement
Thermostat Sensor (Thermister) Replacement Procedure
Step 5.
Fold back insulation just in front of burner to expose temperature sensor (see photo below).
Step 6.
Disconnect temperature sensor from harness (see photos below).
Step 7. Remove temperature sensor (1-1/16" hex, deep well socket) from heater.
Note:
Using a deep well socket will allow room inside socket
for sensor connector and wires.
Step 8. Apply Teflon tape or applicable thread lubricant to threads of new sensor.
Install new thermostat sensor and Connect to wire harness from step 6.
Step 9.
Fold insulation back into place. Be sure there are no wires in contact with burner.
Step 10. Restore 120 volt power supply and water supply to water heater, check and repair any
leaks found. Confirm proper operation following the lighting instructions on the lighting
instruction label or the lighting instruction located in the installation and operating
instruction manual.
Step 11. Replace surround cover on top of heater.
Step 1.
Position main power switch to “OFF”
Step 2.
Disconnect (unplug) water heater from
120 volt power source.
Step 3. Drain water down to the point below
the top of the tank.
Step 4.
Un-latch and remove top surround cover from top of heater.
WARNING
120 volt potential exposure. Isolate the
appliance and reconfirm power is
disconnected using a multi-meter.
Disconnect sensor
from harness
Insulation folded
back to expose
temperature sensor
Summary of Contents for 100-HEC399