background image

BOBRICK

BOBRICK

BOBRICK

Form No. 700-69 Multi Language  (Rev. 7/1/13)    © 2013 Bobrick Washroom Equipment, Inc.    Printed in U.S.A.

Electrical Connection

Check Dryer Operation

Maintenance

Replace Cover

3

1.  Replace cover by positioning  

  top of cover on studs on top  

  of mounting base and tipping  

  bottom of cover toward wall. 

  Push bottom of cover firmly 

  against wall. 

NOTE:

 Space between cover 

and wall must be the same on 

four sides.

2.  To tighten two cover bolts, 

  insert Allen wrench into 

  holes on bottom of cover. 

  Make sure wrench fits into 

  head of cover bolts and 

  turn CoUNTERCLoCkWiSE 

  until bolts are tightened.

NOTE:

 Do not overtighten cover 

bolts; overtightening cover bolts 

may damage enamel finish.

1. 

For TouchButton Hand and Hair Dryers: 

Turn electrical power supply on. Touch the 

  chrome-plated touchbutton once and dryer should turn on. Touch the touchbutton again after 

  a few seconds and dryer should stop. if left on, Hand Dryers will shut off automatically after 30 

  seconds;  Hair Dryers will shut off after 80 seconds.
2. 

For AutoPilot Hand Dryers: 

Turn electrical power supply on. Position hands under nozzle and    

  dryer should turn on. Remove hands from under nozzle and dryer should stop.

FOR PROPER ELECTRICAL CONNECTIONS, CHECK LOCAL BUILDING CODE. UNIT MUST BE INSTALLED BY A QUALIFIED 

LICENSED ELECTRICIAN

1.  Connect dryer to nearest distribution panel. Use wire as required by local electrical code. in the United States and Canada use  

  No. 12 wire or larger.
2.  Wiring instructions:
  a. This appliance is intended for connection to fixed wiring.
  b.  A fused means for disconnection in all poles must be provided in the fixed wiring in accordance with the wiring rules. 
  c.  Check that the electrical rating shown on the Hand Dryer (rating label) is compatible with the electrical supply.
  d.  WARNiNG: THiS PRoDUCT MUST BE EARTHED.
  e.  installation and wiring must conform to current iEE Regulations (Uk), local or appropriate regulation (other countries).
 f. 

For 115 Volt Dryers: 

Connect ground/earth supply the terminal marked       , the Live supply to terminal marked L and neutral  

    supply to terminal marked

 

N

A DEDICATED LINE IS REQUIRED FOR EACH 115 VOLT DRYER.

 

g. 

For 208–240 Volt Dryers: 

Connect ground/earth supply the terminal marked        and the 208-240 Volt wires to terminals  

  marked

 

L (L1)

 and 

N (L2)

.

3.  Secure electrical wire in strain relief clamp provided on mounting base.

WARNING: MOTOR LAMINATIONS ARE LIVE. TURN ELECTRICAL POWER SUPPLY OFF BEFORE DOING ANY 

MAINTENANCE OR SERVICE TO DRYER. DRYER MUST NOT BE OPERATED UNLESS COVER IS IN PLACE.
FOR PROPER ELECTRICAL CONNECTIONS, CHECK LOCAL BUILDING CODE. UNIT MUST BE INSTALLED BY A QUALIFIED 

LICENSED ELECTRICIAN

1.  Exterior of cover should be cleaned with a damp cloth to remove dust and surface dirt. Do not use abrasive agents or solvents as  

  they may

  permanently damage surface of cover.
2.  At least once every 6 months remove cover. Using a small brush or vacuum, clean out buildup of dust and lint from air-intake grille  

  and baffle.

NOTE:

 if dryer is installed where there is a lot of dust and dirt in the air, the interior of the dryer should be cleaned out more 

frequently.

Summary of Contents for B-700

Page 1: ...Form No 700 69 Multi Language Rev 7 1 13 2013 Bobrick Washroom Equipment Inc Printed in U S A INSTALLATION INSTRUCTIONS B 700 B 708 B 770 B 778 SURFACE MOUNTED AUTOMATIC HAND DRYER 1 ...

Page 2: ... by pulling forward at the bottom and upward at the same time Hand Dryer Bobrick automatic hand dryers should be installed 15 380mm above any projection or horizontal surface which may interfere with the operation of the automatic sensor 1 Hold the Installation Template against the wall in the desired location of the installed dryer See recommended mounting heights above 2 Make sure line on templa...

Page 3: ...ger 2 Wiring Instructions a This appliance is intended for connection to fixed wiring b A fused means for disconnection in all poles must be provided in the fixed wiring in accordance with the wiring rules c Check that the electrical rating shown on the Hand Dryer rating label is compatible with the electrical supply d WARNING THIS PRODUCT MUST BE EARTHED e Installation and wiring must conform to ...

Page 4: ...at the option of Bobrick Washroom Equipment Inc THISWARRANTY DOES NOT COVER ACCIDENTAL DAMAGE IMPROPER HANDLING OR INSTALLATION OR REPAIRS MADE BY UNAUTHORIZED PERSONS AND SPECIFICALLY EXCLUDES CLAIMS FOR INDIRECT ACCIDENTAL OR CONSEQUENTIAL DAMAGESTO PROPERTY THE IMPLIEDWARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITEDTOTHE SAME DURATION OFTHE ABOVEWARRANTY Some state...

Page 5: ...mail Bobrickcustomerservice bobrick com In Canada BOBRICKWASHROOM EQUIPMENT COMPANY 45 Rolark Drive Scarborough Ontario M1R 3B1 FAX 877 423 8555 International BOBRICKWASHROOM EQUIPMENT INC 11611 Hart Street North Hollywood CA 91605 5882 818 764 1000 FAX 818 503 9941 BOBRICKWASHROOM EQUIPMENT Pty Ltd Australia 1 818 764 1000 FAX 1 818 503 9941 BOBRICKWASHROOM EQUIPMENT Limited United Kingdom 44 0 2...

Reviews: