Page | 8
• Improper use of the battery could cause it to leak. If this
happens it will need to be replaced and properly recycled.
Please do not touch any leaking material from this battery.
If you come in contact with the battery liquid flush with
clean water and seek medical attention immediately.
• When not in use, store this tool carefully in the supplied
case. It can be washed with a soft cloth and soapsuds after
you finish work. Do not use petrol chemicals or alcohol to
clean this tool.
• In the event that this tool malfunctions or drops in per
-
formance you can call our Customer Service Repair Center
(800) 992-3833 or send us a note to [email protected]
BN Products-USA
3450 Sabin Brown Road
Wickenburg, AZ 85390
(800) 992-3833 • [email protected]
Common Faults
Warning
Sound
Indicator
Light
Items To Inspect
Possible Cause
Actions
The machine does not
work after
putting in a new wire
spool.
None
Off
Inspect the battery
terminal
Oxidation or there
is dirt on the elec-
trodes
Use a dry cloth to
wipe the surfaces
Beep----
On-
Confirm that the battery
is charged
Low power in the
battery
Recharge the battery
Beep,
Beep,Beep
On Off On Off
On off...
Check wire guide “A” to
see if there is stray wire in
the guide
The head of the wire
was caught in the
guide
Using a pair of pliers
remove the wire
Beep, Beep,
Beep, Beep...
On Off On Off
On off...
Check the curl guide to
see if there is a stray wire
caught in the tool
Tying strength may
be to strong
Adjust the tying
force and remove the
caught wire
The wire does not feed
correctly
Beep, Beep
On Off On Off
On off...
Check the curl guide
The curl guide is
open
Close the curl guide
Beep, Beep,
Beep
On Off On Off
On off...
Check the diameter of the
rebars
The diameter of the
rebar exceeds chart
Use the proper diam-
eter rebars
Beep, Beep,
Beep, Beep...
On Off On Off
On off...
Check the tightness of the
wire coil
The wire is too tight
on the coil
Clear the winded wire
Irregular binding and
wire stepping out of
the curl guide
None
On-
Alarm when pressing the
trigger- No alarm when
released
Overheated motor
from constant use
Let the motor cool
down
Failure to cut the wire
after binding
None
On-
Check if the wire hits the
rebar when tying
The wire hitting the
rebar will stop the
action
Pay attention so that
the wire does not hit
the rebar
Tying knot is loose
None
On-
Check to see if the cutting
mechanism is working
correctly
There may be a stray
piece of wire in the
cutting mechanism
Clean the cutting
mechanism
None
On-
Check the operation
instruction
Wrong operation
Please read the
operation manual
Tying knot is not cor-
rect
None
On-
Check the tying strength
The tying force is
too great
Adjust to the proper
tying force
Common Faults
This tool alerts you to the following fault conditions by means of a warning sound and warning light. If the problem is not
solved please contact our maintenance support department: (800) 992-3833.