BN Thermic Ltd,
34 Stephenson Way,
Crawley, RH10 1TN
Tel: +44 (0) 1293 547361
Email: [email protected]
Web: www.bnthermic.co.uk
This product conforms to EU Directive 2002/96/EC.
This appliance bears the symbol of the crossed waste bin. This indicates that, at the end of its useful life, it must not be disposed of as
domestic waste, but must be taken to a collection centre for waste electrical and electronic equipment. It is the user's responsibility to
dispose of this appliance through the appropriate channels. Failure to do so may incur penalties established by laws governing waste
disposal.
Pic. A
Pic. B
Pic. C
7. COMMISSIONING
Note:
The infrared lamps in the heater are fragile as such it is important that they are not subjected to any unnecessary shocks or vibration and are
not moved when in use. Wait till the heater has cooled down before moving / adjusting.
WARNING! Ensure you read, understand and apply the safety instructions in Section 1 before using the heater.
7.1 Perform Insulation and Earth continuity tests.
7.2 Switch on the heater(s) and confirm that the lamps are working.
7.3 Ensure each heater aims its warmth into the target area by adjusting the heater angle(s) as required, and then tighten the bracket bolts
keeping the heater(s) firmly in place.
7.4 Although the fitting can be tilted between 30º & 45º in the vertical plane, check & ensure that the fitting remains within 10º
of the horizontal
plane as the lamps are only designed for horizontal operation.
7.5 The User / Customer should be made aware of all aspects of the operation and safety advice. Keep the instructions safely for future
reference.
7.6
In unoccupied premises it is recommended that the heating system is switched off and isolated from the electrical supply.
Magic Lamps (if installed) are designed to glow red for a few minutes before dimming to a gentle pink glow.
8. MAINTENANCE
Note:
Before examining or carrying out any maintenance ensure the heater has cooled down and is disconnected from the mains supply.
8.1
BN Thermic infrared quartz heaters contain no moving parts and therefore very little maintenance is required other than to ensure that there
is no excessive build-up of dust/dirt on the reflectors or lamps as this can cause overheating and premature lamp failure. Depending on
installation conditions, a heater should be regularly inspected, but at least once per year.
9. LAMP REPLACEMENT
Note:
Before examining or carrying out any maintenance ensure the heater has cooled down and is disconnected from the mains supply.
The lamp used in the fitting is robust and if knocks and shock vibrations are avoided, will last for around 7000 hours.
Lamp Installation (if required) or replacement
1) Undo the 4 screws on each end cover, and remove the covers (Pic. A).
2) Unscrew the 4 screws securing the guard (Pic. B), remove guard and slide out the end reflectors.
3) If replacing lamp unscrew lamp leads and remove lamp.
4) Carefully remove new lamp from its box making sure you do not touch the glass
part of the lamp, centre lamp to brackets with leads pointing downwards.
5) Insert each end of lamp halfway under each spring clip.
6) Push slowly each end of lamp with equal thumb pressure fully into clips (Pic. C).
N.B. Any inadvertent finger marks on the glass lamp can be removed using
methylated spirits on a soft cloth.
7) Connect lamp leads to connector blocks. Tighten screws.
8) Re-assemble heater by sliding the end reflectors back, then secure the guard in position with the 4 screws.
9) Refit the end covers making sure no wires are trapped before tightening the screws.
10) WARNING! Failure to reassemble all the parts and use the guard will invalidate any remaining guarantee and may make the unit dangerous.
10. SPARES
Note:
Spare Lamps are available from your distributer. Please quote the following Lamp codes when requesting spares
Heater Model
HN3-30(B)
HN3-30(B)M
Replacement Lamp Code
RL15GF
RL15MF
NOTE: It is our policy to continually improve products and as such we reserve the right to alter specifications and component parts without prior notice.
IMPORTANT:
No liability is accepted for incorrect use of this product.
WARRANTY:
Your BN Thermic product is guaranteed for one year from date of purchase. We will
repair or replace at our discretion any part found to be defective. We cannot assume any
consequential liability. This guarantee in no way prejudices your rights under common law and is
offered as an addition to consumer liability rights.
REGISTER:
Activate your warranty by registering online at www.bnthermic.co.uk and retain this
installation data for future reference.
HN3-2INS-v01