Back View of CS2
Mains Cable
Back View of Heater
Switch link Cable - Use
1.5mm² 4 Core Cable
(see note above)
5. CONNECTING A CS-2 CONTROL SWITCH TO THE HEATER
CS-2 control switch box can be easily connected to the
HN3-30
Heater. This will allow the heater to be operated with one or two lamps so
controlling the heat output.
Please make sure you have read the Safety instructions and that you are a suitably qualified electrician before continuing.
Drawings show connections inside the terminal box on the outside of the heater and the inside of the CS2 Controller.
Please Note:- Specified cable sizes are for typical installations, correction factors may need to be used when determining actual cable sizes.
Follow the following instructions to connect the heater to CS-2 Switch Box
a) Open terminal box on back of heater.
b) Remove blanking plug in the heater connecting box and fit cable gland to suit cable you are using (not supplied).
c) Remove Brown Link cable between L - L1 and L1 - L2.
d) Use 4 core silicon cable having a temperature rating of 180ºC or other suitable cable that will withstand 85ºC continuously.
e) Connect the cable as per drawings below.
f) Switch box CS2 MUST be earthed.
6. CONNECTING CONTROLS TO MULTI-HEATERS
Using our MC1 Halogen Heater Control Boxes you can connect many heaters together controlling them from one source.
These control boxes feature: -
• Soft Start (stops the large inrush of power when turning multi heaters on together)
• Full Power or 1/2 Power from a single switch
• Internal countdown timer if required (can be set between 10-140 Minutes)
• Facility for adding many other controllers including PIR, Frost Thermostat, Room Thermostat (stops heaters working if temp
above set point) Timers etc
• Individual fusing of each lamp.
If you require further information on multi-heater controllers please contact us using the number on the back page.