The over-current protector is in the “OFF” position when the protector switch
is raised. Press the button of the AC over-current protector to the “ON’ posi-
tion to reset the protector. If the circuit breaker is switched OFF automatically,
switch the circuit breaker ON again.
GENERATOR OPERATION
Generator Operation Environment:
• Temperature: -41°F ~104°F
• Humidity: Below 95%
• Height above sea level: 3000ft or lower (If the area is above 3000ft, the
power output will be slightly lower).
It is not recommended to connect this generator to your building’s electrical
power. This can potentially back feed electricity to the utility lines, putting
utility workers’ lives at risk while performing repairs. Instead, if you need a
backup generator or “whole house” standby power, please consult a qualified
electrician to help you determine the best solution for your needs.
It is acceptable to run individual appliances only if they are directly plugged into
the generator and are within the generator’s rated capacity. Do not run a gener-
ator inside your home for any reason. Make sure it is outside in a well-ventilated
area
AC Current
Before starting the generator, make sure the total load appliance power (the
total resistance, capacitive and inductive) does not exceed the generator’s rated
capacity.
Overloading this generator will significantly shorten the generator service life. If
the generator is connected to multi-loads or several electric appliances, please
connect the largest load first, then the second-largest load, followed by the
lightest load.