Electrical data
Version with charging socket:
Type 2 standard socket with shutter: 32 A/400
VAC to EN 62196-1 and EN 62196-2
Protection class:
I
Device's IP protection class:
IP54
Protection against mechanical impact:
IK08
Interfaces
Enable input [X1]:
Enable input for external authorisation:
Connection cable:
- Cross-section (min.-max.): 0.08 – 4 mm²
- AWG (min.-max.): 28 – 12
RS485 connection [X2]:
Extra-low safety voltage <50 V
Connection cable:
- Cross-section (min.-max.): 0.08 – 4 mm²
- AWG (min.-max.): 28 – 12
Diagnostic connection [X3]:
RJ45
Ethernet1 connection [X4]:
LSA+ terminals
USB connection [X5]:
USB jack type A (max. 500 mA)
RFID (optional):
MIFARE cards or tags to ISO 14443 or ISO
15693 Tag-It
or Tag-It cards or tags to ISO 15693
Mechanical data
Dimensions (W x H x D)
399 x 652 x 202 mm (without connector)
Weight:
approx. 10 kg (depending on version)
Assembly (stationary):
On the wall or on the column