DIP switch settings
The use of the domestic connection monitoring
function with RS485 meters must be selected
using a DIP switch setting and does not come
into effect until the Wallbox has been restarted.
If no meter
5
is found when the ModBus function
has been enabled, the charging current is
reduced to 10 A.
No monitoring: DSW1.2 =
OFF
(default)
Monitoring function: DSW1.2 =
ON
This reduction is also visualised on the Wallbox
status LED. Further information is provided in the
Wallbox operating manual.