ELECTRICS
Connection diagram with open termination panel cover
1
Mains connection outer conductor 1
T1
Service button
2
Mains connection outer conductor 2
LED
Status LED, internal
3
Mains connection outer conductor 3
X1
Enable input
N
Mains connection, N conductor
X2
RS485 connector
PE
mains connection, PE conductor
X3
Diagnostic connector, RJ45
F1
Fuse holder
X4
Ethernet1 connector, LSA+ terminals
DSW1
DIP switch for configuration
X5
USB connector
DSW2
DIP switch for addressing
Shd
Shield connection for Ethernet1
connection terminals
IMPORTANT
The X3 diagnostic connection is suitable only for error analysis and must not be used to
connect the device to a network.
Note
The connection overview shows all the options of the device, but the legend only lists the
available options. It is possible that your version of the device will not have all the connections
available.