15
Installing the Indoor Unit (IDU)
Figure 6 TCII Indoor Unit
To install the Truck-Coder II Indoor unit:
The TCII Indoor unit is designed to fit in a standard 19” rack using either permanent shelf or rails to
support the IDU. A mounting kit (BMS P/N 7614191020) is included if needed.
Select a location to mount the unit. There needs to be enough space around the unit to allow for proper
ventilation and access to connections.
Warning:
Failure to ensure proper ventilation could cause the system to overheat resulting in system failure and
possible damage. Do not block the intake or exhaust fan vents
1.
Make the appropriate connections to the back panel (see Figure 7). Be sure that all connections are
secure. Route the cables as needed.
2.
Slide the IDU into position so that the front panel is flush with the rack.
3.
Using 4 each, #10-32 ½ in long pan head screws, flat washers and split-lock washers, secure the IDU
to the rack.
4.
Install the ODU on to the antenna mast.