Error Description
Cause
Fixing
Incorrect connection cable
or wiring fault
> Check cable for proper Pinout.
> Verify at USB cables that it's
length is not longer than 2m
> Try to use original BMR
cables, only
In case of using RS232
> Use the USB-Interface at the
PC together with a USB-RS232
converter.
> For use with SFU 0303 a
specific
RS232 cable is required
In case of using a USB-RS232
converter the USB-driver is not
installed correctly.
install driver
unsure
Restart SFU-Terminal
Start with
push
buttons
not possible
Start button deactivated
Enable Start button by un-
checking the checkbox "Block
Start Button"
An input is assigned with the
function
Emergency Stop
and
configured as "Low Active."
> This is default state on
delivery
> For unlocking, a signal of
"HI" / +24V is required at this
input.
> Deactivate this function or
setup as "High Active"
The evalution of the
temperature sensor is activated
in the spindle characteristic, but
it is not connected or a sensor
isn't implemented
within the spindle
-> in this case Error is indicated,
additionally
> Connect the temp sensor
wires with the SFU.
> uncheck the button "Temp
Sensor" in the spindle
characteristic in SFU-Terminal
The spindle test is engaged
> Check cable and connections
for proper wiring or short circuit
> Check spindle
In case of connecting the
converter with a PC or
after launching the SW
SFU-Terminal the
Converter is not detected
and not recognized
Spindle does not start, in
spite of a valid signal for
Start
Summary of Contents for SFU 0303/4
Page 1: ... when it comes to quality BMR GmbH 1 ...
Page 2: ...2 SFU 0303 Frequency Converter ...
Page 7: ... when it comes to quality BMR GmbH 5 3 Block Diagram ...
Page 42: ...40 SFU 0303 Frequency Converter 16 2 19 Version ...
Page 43: ... when it comes to quality BMR GmbH 41 16 3 Version Desktop ...
Page 44: ...42 SFU 0303 Frequency Converter 16 4 Version Desktop 63TE ...