24
LVD MODE
LEAD-ACID
LiFePO4
ECO Mode
10.8V
12.0V
Storage Mode
10.5V
11.5V
Table 3:
LVD Mode voltage thresholds
The ASPower will enter the two stages of LVD, ECO Mode and Storage Mode,
when the caravan’s battery voltage falls below the LVD thresholds.
ECO MODE
The ASPower will enter ECO Mode if the the battery voltage runs low or if the
ECO Mode button is pressed on the ASDisplay.
When in ECO Mode, all outputs on the ASPower except output 14.are turned off
including the water pumps, however the CAN power will remain on, meaning the
ASDisplasy will remain functional.
ECO Mode will be exited if either the the ECO Mode button is pressed again on
the ASDisplay, or battery charging begins.
If the ECO Mode button is not pressed on the ASDisplay, and the battery is
charging, the ASPower will exit ECO Mode when the battery is sufficiently
charged. Upon exit of ECO Mode, the ASPower will automatically return to its
previous state of operation.
When in ECO Mode you may temporarily turn on caravan loads by cycling the
caravan’s Load Isolation Switch. This allows you to retract slide-outs or electric
steps if you need to pack your caravan.