7
7
Picture 4
Mount the device on the multi-functional adapter.
(1) Set up the device in the middle of an approx. 6x6 m room (picture 4). Switch all laser
lines
(Button 1 press 4x)
(2) Let the laser level itself ,then mark the intersection of laser lines A and all dots
( B, C, D and E)
(3) Turn device about 90° around plumb axis of dot E, until the laser dot C is on the mark
D. Mark the points A´, B´ und D´.
(4) Measure the distance between A
– D
ˊ
, B
– A
ˊ
und C
– B´
If all deviations are less than 2 mm, the device is conform and respects the
tolerances