5
5
Abbildung 2
5. Accuracy Check
Before the activation, a drop or a hit we recommend to run a check up
of the device
; otherwise the manufacturer’s liability is expired.
5.1 Checking accuracy of the horizontal laser line and laser dots pointing
right, left and forward
Mount the device on the multi-functional adapter.
Select 2 walls in a distance of a minimum of 5m from each other.
(1) Place the device with a distance of ca. 10 cm in front of Wall 2.
(2) Disengage the transport lock, press
button 1
. The device levels out automatically.
(3) Mark the intersection of horizontal and vertical lines of the cross line (Marking pointA)
(4) Turn the device around 180° without changing the height. (picture 1)
Mark the intersection of the cross line (Marking point B).
(5) Put the device with a distance of ca. 10 cm in front of Wall 2. Mark intersection of
horizontal and vertical lines of the cross line (Marking point B)
(6) Turn the device around 180° without changing the height.
Mark the intersection of the cross line (Marking point A1) ( picture 2)
(7) Messen Sie
den Abstand zwischen „A“ und „A1“.
If the marking points A and A1 are identical, the device is conform:
Fläche 1
Picture 2
Wall 1
Wall 2
A1
Section of measurements „S“ 5 m
picture
1
wall 2
wall 1
B
A