![BMB e-mo-lift Series Assembly Instructions / Operating Manual Download Page 6](http://html1.mh-extra.com/html/bmb/e-mo-lift-series/e-mo-lift-series_assembly-instructions-operating-manual_2779541006.webp)
6/8
BMB
Art. 6256.065 e-mo-lift 650
Art. 6256.100 e-mo-lift 1000
In case the TV-lift does not operate properly, make sure, that all cables are attached to the TV-lift and
disconnect the power plug for a few seconds. Plug the power back in and make certain, that the green
control lamp on the control box is on. Maybe a RESET is necessary. If yes, please follow the instructions
as outlined in „OPERATING – How to reset“.
• In case none of the buttons work when pushed, please perform a RESET.
• In case the motor acts unusual, please perform a RESET. In case the problem remains,
please contact your seller.
• Should the lifting column move constantly for more than 3 minutes, a safety mechanism is activated.
The system is put out of order, the buttons no longer work. As soon as the system changes to safety
mode, the red light of the pushbutton flashes every 3 seconds. After about 16 minutes the system
should be back fully operational.
TROUBLE SHOOTING
You can operate the TV-lift by using the remote control or the pushbutton.
The pushbutton supersedes the remote control.
You can operate the TV-lift by pushing
and
on the remote control
or by pushing „UP/DOWN“ on the pushbutton.
• constantly, until the desired position is reached (constant-touch-mode)
•
once, until the desired position is reached, then again to stop the TV-lift in that position
(one-touch-mode).
The pushbutton and the remote control are set in the one-touch-mode when first delivered.
IMPORTANT: Before you use the TV-lift it is important to perform a reset.
How to reset the TV-lift
:
DPush the reset button on the pushbutton for 5 seconds. The red light on the pushbutton
flashes once, indicating the RESET-mode.
Then, let go of the button. After that, push the button once again until the lift column reaches
the bottom, moves up about 7mm and stops. Once the red light turns off, the reset has been
completed.
• The flash pattern during a reset (flashes every 0,5 seconds) differs from the flash pattern
during working mode (flashes every 3 seconds).
• While resetting, the constant-touch mode is activated.
• During the reset, only the RESET-button of the pushbutton is functional.
• In case the lift column was moving when initiating a RESET, the movement will be stopped.
• A RESET must be completed for the system to be fully operational again.
OPERATING