8
Getting
started...
Planning your Installation
BLY1
Wireless Alarm System
Zone Number
Area
Zone
Area
1
Front Door
5
Area of the
control panel
2
Back Door
6
Kitchen
3
Window
7
Bedroom 2
4
Window
8
Bedroom 3
The PIRs have been separately placed in bedroom 1, bedroom 2, bedroom 3, and the area
where the control panel is installed, to protect these areas. The Door/Window contact detectors
have been positioned to protect the front door, back door and windows on the 1st floor.
Sample 2:
Front door
ZONE 1
Window
ZONE 4
Window
ZONE 3
Living
Room
Bedroom
1
Bedroom
2
Dining
Room
Wirefree
External Siren
ZONE 8
ZONE 7
Back Door
ZONE 2
Control Unit
Kitchen
ZONE 6
ZONE 5
The Zone 5 PIR has been placed in the dining room to protect this area where the control panel
is installed. The zone 6, 7, 8 PIRs have been separately placed in the kitchen, bedroom 1
and bedroom 2 to protect these area. Zone 6, 7 and 8 are set as “Home-Bypass zone” so that
these PIRs are disabled when the system is set to “Part Arm” mode. The Door/Window contact
detectors have been positioned to protect the front door, back door and windows.
When the system is installed for the first time or any further detectors are learned to it at any
stage, please follow sections 3.1 to 3.5 explained in this manual to prevent the tamper function
from unnecessarily triggering the alarm of the control unit during installation.
Summary of the steps:
1. Install and power ON the control unit
2. Power up the wireless devices and link to the control unit
3. Power OFF the control unit
4. Install the detectors in their final locations
5. Install the backup battery in the control unit and finally power up the control unit
Wireless Alarm System.indd 9
01/06/2012 10:57