similar product may be used with a soft bristle brush to remove any mineral deposits that may 
have developed.  It is recommended that you use Fountec™ to prevent the formation of algae in 
conjunction with Protec™ to prevent the build up of mineral deposits.  For your convenience, we 
have Fountec™ readily available.  Please call customer service. 

 

b.

 

Water Wonders Fountains 

Check to make sure there is no debris blocking any of the grooves.  If calcium or algae has built 
up in the groves, use a pipe cleaner to carefully remove the blockage.  Use caution as to not 
damage the panel as the slate is very thin and can be brittle.  It is recommended that you use 
Fountec™ to prevent the formation of algae in conjunction with Protec™ to prevent the build up 
of mineral deposits.  For your convenience, we have Fountec™ readily available.  Please call 
customer service. 
 

6.

 

Dirty  filter (Water Wonders units, Trellis, Be

llezzas,  Contempos, Watergardens, Piavascos and 

Serrano Horizontal fountains do not have filters). 

 

Remove re-usable filter from pump, clean and re-install. 

 
7.

 

Pump is clogged or malfunctioning

 

 

Refer to pump cleaning instructions.  If still not working, unplug the fountain contact customer 
service. 

 
 

WATER FLOW IS TOO SLOW/FAST 

1.

 

Flow valve is not set properly

 

 

Locate the water flow control valve between the pump and the inlet hose.  

The flow valve on Water 

Wonders fountains, Table Tops , Bellezzas, Piavascos and Water Ga rdens is a black  disc located on 

the top of the pump.

  Turn the valve clockwise to slow the water flow, counter-clockwise to increase 

it. 

 
2.

 

Blockage in water distribution bar which is located above the panel

 

a.

 

Bluworld Fountains 

 

Remove the distribution bar by carefully twisting the bar back and forth until it disconnects from 
the PVC elbow.  Thoroughly clean the distribution bar and reinsert into the PVC elbow.  You can 
use a pin, pipe cleaner or small wire to clean any debris from the holes in the manifold distribution 
bar.  A long, narrow brush may also be used to clean the inside of the pipe.  CLR or any other 
similar product may be used with a soft bristle brush to remove any mineral deposits that may 
have developed.  It is recommended that you use Fountec™ to prevent the formation of algae in 
conjunction with Protec™ to prevent the build up of mineral deposits.  For your convenience, we 
have Fountec™ readily available.  Please call customer service. 

 

b.

 

Water Wonders Fountains 

Check to make sure there is no debris blocking any of the grooves.  If calcium or algae has built 
up in the groves, use a pipe cleaner to carefully remove the blockage.  Use caution as to not 
damage the panel as the slate is very thin and can be brittle.  It is recommended that you use 
Fountec™ to prevent the formation of algae in conjunction with Protec™ to prevent the build up 
of mineral deposits.  For your convenience, we have Fountec™ readily available.  Please call 
customer service. 

Summary of Contents for WATER WONDERS Waterfall

Page 1: ...Copyright 2009 Bluworld of Water LLC All rights reserved Waterfall Manual...

Page 2: ...bmerged This will only have to be done the first time the unit is turned on 6 Using the red or blue handle on the hose valve adjust the flow of the water to the desired effect Too much flow can cause...

Page 3: ...n the fountain off instead of letting them dry on the fountain FOUNTAIN SHOULD BE LEVEL Make sure your waterfall is always kept level For floor fountains you can try using a shim coin thin plastic etc...

Page 4: ...also be used to clean the inside of the pipe CLR or any other similar product may be used with a soft bristle brush to remove any mineral deposits that may have developed DO NOT use CLR or Lime Away...

Page 5: ...in the water level at least 2 above the water pump but below the hole where the electrical cords run through The pump should be completely submerged underwater and should be checked every 3 4 days 2 F...

Page 6: ...difference from one end of the bracket to the other you will want to remove the bracket and reinstall it making certain it is level If the difference is minute a shim or tiny wedge can be placed on t...

Page 7: ...between pump and inlet hose until water flows evenly down the panel The flow valve on Water Wonders fountains Table Tops Bellezzas Piavasco s and Water G ardens is a black disc located on the top of t...

Page 8: ...the inlet hose The flow valve on Water Wonders fountains Table Tops Bellezzas Piavascos and Water Ga rdens is a black disc located on the top of the pump Turn the valve clockwise to slow the water flo...

Page 9: ...cut it will need to be replaced 4 Water flow is too strong Locate the water flow control valve between the pump and the inlet hose The flow valve on Water Wonders fountains Table Tops Bellezzas Piavas...

Page 10: ...imple Green or other appropriate cleaner Be sure detergent is safe to use on the surfaces you are cleaning 4 Waterfall might have scale deposits from water Drain and refill the fountain with fresh wat...

Reviews: