HEX70HDU-KIT
USER MANUAL
www.blustream.com.au | www.blustream-us.com | www.blustream.co.uk
18
COMMAND
ACTION
EDID xx CP yy
Set Input xx EDID Copy From Output yy
EDID SAVE zz
Save EDID File From PC Into User Slot zz
zz=22: User EDID 1
zz=23: User EDID 2
RELAY xx MODE yy
Set Relay xx to Mode yy
xx = 00 : All Relays
xx = 01 : Relay 1
xx = 02 : Relay 2
yy = 01 : Disable NO And Enable NC
yy = 02 : Enable NO And Disable NC
RELAY1 xxx
Set The Relay Delay 1 Time To xxx.(Default 10s,
Range From 3s To 180s) Triggered When System On.
If xxx = 000 Relay 1 Will Remain Active Until System
Off(For Fixed 5V/12V Signal Sensing).
RELAY2 xxx
Set The Relay Delay 2 Time To xxx.(Default 10s,
Range From 3s To 180s) Triggered When System Off.
OUT xx PON
Send Output xx CEC And RS232 Power On Command
OUT xx POFF
Send Output xx CEC And RS232 Power Off Command
OUT xx VOLUP
Send Output xx CEC And RS232 Vol Up Command
OUT xx VOLDOWN
Send Output xx CEC And RS232 Vol Down Command
OUT xx MUTE
Send Output xx CEC And RS232 Mute Toggle
OUT xx INPUT yy
Send Output xx CEC Input Channel yy
xx = 01 : RX HDMI Output
yy = 00 : Next HDMI Channel
yy = [01...15] : HDMI Channel 01 To HDMI Channel 15
IN xx CEC POWER
Send Input xx CEC Power Toggle Command
xx = 01 : TX HDMI Input
xx = 02 : RX HDMI Input
RS232BAUD z
Set RS232 Baud Rate To z
z = 1 2400, 2 4800, 3 9600, 4 19200, 5 38400, 6 57600
(default), 7 115200"
COMMAND
ACTION
RS232ON x:y:z:a
Send y Type Of Command a Stored In Slot x Whose
Baud Rate Is z
x = 1 Send RS232 Display On
x = 2 Send RS232 Display Input Select
x = 3 Send RS232 User Command 1
x = 4 Send RS232 User Command 2
x = 5 Send RS232 Volume Up
x = 6 Send RS232 Volume Down
x = 7 Send RS232 Volume Mute
y = a ASCII, h HEX
z = 1 2400, 2 4800, 3 9600, 4 19200, 5 38400, 6 57600
(Default), 7 115200
a = RS232 Command
RS232OFF y:z:a
Set RS232 Off Command a Of y Type Whose Baud
Rate Is z
y = a ASCII, h HEX
z = 1 2400, 2 4800, 3 9600, 4 19200, 5 38400, 6 57600
(Default), 7 115200
a = RS232 command
RS232ON DISABLE
Disable Auto RS232 Commands When Detecting A
Signal
RS232OFF DISABLE
Disable Auto RS232 Commands When Not Detecting
A Signal
RS232RPT x
Set x Number Of Times RS232 OFF Command Is
Repeated (Default 1 Time, Range From 1 Time To 2
Times)
RS232RPTDLY xx
Set The Sending Interval Time In xx Second(s)
Between RS232 OFFs (Default 2s, Range From 1s To
10s)
RS232INPUTDLY xx
Set The Sending Interval Time In xx Second(s)
Between RS232 ONs (Default 10s, Range From 1s To
30s)
NET IP
xxx.xxx.xxx.xxx
Set IP Address
NET GW
xxx.xxx.xxx.xxx
Set Gateway Address
NET SM
xxx.xxx.xxx.xxx
Set Subnet Mask Address
NET RB
Set Network Reboot and Apply New Config
NET TN xxxx
Set Telnet Port
NET DHCP ON/OFF
Set Auto IP(DHCP) ON Or OFF
RS-232 Configuration and Telnet Commands
Summary of Contents for HEX70HDU-KIT
Page 1: ...HEX70HDU KIT User Manual RevA0_HEX70HDU KIT_Manual_201123...
Page 21: ......