32
EN
TROUBLESHOOTING
Problem
Condition
Solution suggested
Burner will not light.
Control knob is not in
maximum position (big
flame).
Turn control knob in
maximum position (big
LPG cylinder valve is
closed /empty
Open the valve / Replace
LPG cylinder with a new
one.
Blockage in the injector.
Clean or replace injector.
Air in the gas circuit.
Open gas line and bleed it
(pressing control knob in)
for not over 1 minute or
until you smell gas.
Low gas pressure.
Replace LPG cylinder with
a new one.
Igniter fails.
Use match to light burner;
change battery or obtain
new ignite and replace it.
Burner will not stay lit.
Dirty build up around
burner.
Clean dirty around the
burner.
Low flames or not full
running around the burner.
Flame spreader holes
partially closed; clean the
burner.
Thermocouple is not
operating correctly.
Replace thermocouple
(FSD).
Low Gas pressure.
Replace LPG cylinder with
a new one.
Burner flame is low
Note: Do not operate
appliance below 5 ˚C
Outdoor temperature is
greater than 5 ˚C and LPG
cylinder is less than 25
% full.
Replace LPG cylinder with
a new one.
Gas pipe is bent or kinked.
Straighten hose and
perform leakage test on
gas pipe.
Control knob is fully
maximum position (big
flame).
Turn control knob to”OFF”
position (full disk), let cool
to room temperature and
check burner and orifices
for blockage.